<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>16 25 35 50 70 95 120 150 185 240 300 CABLE &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/16-25-35-50-70-95-120-150-185-240-300-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Thu, 19 Mar 2020 19:16:30 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>CU/XLPE/PVC electric cable 11kV 33kV 150 185 240 300 copper wire screened MV cable</title>
		<link>https://german.baoliyy.com/cu-xlpe-pvc-electric-cable-11kv-33kv-150-185-240-300-copper-wire-screened-mv-cable/</link>
				<comments>https://german.baoliyy.com/cu-xlpe-pvc-electric-cable-11kv-33kv-150-185-240-300-copper-wire-screened-mv-cable/#respond</comments>
				<pubDate>Thu, 19 Mar 2020 19:16:30 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[shancable]]></category>
		<category><![CDATA[11kV 33kV copper wire screened MV cable]]></category>
		<category><![CDATA[16 25 35 50 70 95 120 150 185 240 300 CABLE]]></category>
		<category><![CDATA[CU\/XLPE\/PVC electric cable]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/cu-xlpe-pvc-electric-cable-11kv-33kv-150-185-240-300-copper-wire-screened-mv-cable/</guid>
				<description><![CDATA[Cu/vpe/pvc elektrokabel 11kv 33kv 150 185 240 300 kupferdraht abgeschirmtes mv-kabel &#160; Vpe( Kreuz- verbunden Polyethylen) isoliert, pvc-ummantelte mv-kabel Kupferdraht + kupferband bildschirm Sta/SWA/awa r&#252;stung Iec 60502, iec 60228, iec 60332, ce, kema &#160; Konstruktionen Leiter Kompakte kupferlitze, Klasse 2 nach iec 60228 Rundschreiben massiver kupferleiter, Klasse 1 nach iec 60228 Flexible kupferlitze, Klasse 5 [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<h2>Cu/vpe/pvc elektrokabel 11kv 33kv 150 185 240 300 kupferdraht abgeschirmtes mv-kabel</h2>
<h2>&nbsp;</h2>
<h3><span style="font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px">Vpe( Kreuz- verbunden Polyethylen) isoliert, pvc-ummantelte mv-kabel</span></h3>
<h3><span style="font-size: 12.0px">Kupferdraht + kupferband bildschirm</span></h3>
<h3><span style="line-height: 17.6px;font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px">Sta/SWA/awa r&uuml;stung</span></h3>
<h3><span style="font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px">Iec 60502, iec 60228, iec 60332, ce, kema</span></h3>
</p>
<div id="J-rich-text-description">
<p align="left">&nbsp;</p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Konstruktionen</span></strong></p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 14.25pt" align="left">
<td style="width: 130.65pt;height: 14.25pt" rowspan="3">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Leiter</span></p>
</td>
<td style="width: 301.7pt">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Kompakte kupferlitze, Klasse 2 nach iec 60228</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Rundschreiben massiver kupferleiter, Klasse 1 nach iec 60228</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Flexible kupferlitze, Klasse 5 nach iec 60228</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Leiter bildschirm</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Semi- Leiter( mv nur)</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">isolierung</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Vpe( Kreuz- verbunden Polyethylen)</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">bildschirm isolierung</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Semi- Leiter( mv nur)</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">separaten Bildschirm</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Kupferdraht + Band( mv m&uuml;ssen, lv optional)</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">f&uuml;llstoff</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Pp garn, oder Papier</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">wickelband</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">pp</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">innere f&uuml;r</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Extrudierte pvc( mv nur)</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">r&uuml;stung</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">Stahldraht, oder stahlband, oder aluminiumband optional</span></p>
</td>
</tr>
<tr style="height: 14.25pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">insgesamt mantel</span></p>
</td>
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">pvc oder pe</span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Anwendungen</span></strong></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt">F&uuml;r energie&uuml;bertragung und-verteilung Einklang mit Spannung bewertet 35kv und unten. Verglichen mit pvc-stromkabel, vpe stromkabel bietet nicht nur Eigenschaften von ausgezeichneten Strom, mechanismus, W&auml;rme und Alterung- best&auml;ndig, Umwelt Stress- best&auml;ndig und chemische korrosion- best&auml;ndig, sondern auch einfache Struktur, leichte, keine Beschr&auml;nkung durch Auflegen drop, und hoher Temperatur Zulage f&uuml;r Langzeit- arbeiten.</span></p>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt">&nbsp;</span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Standards</span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Internationalen: iec 60502- 2, iec 60228</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">china</span><span style="font-family: arial;color: #231f20;font-size: 10.0pt">: gb/t 12706.2-2008</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">andere Standards wie</span><span style="font-family: arial;color: #333333;font-size: 10.0pt">Bs, din und ICEA auf Anfrage</span><strong></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">&nbsp;</span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">technische Daten</span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Nennspannung: 0.6/1kv, 1.8/3kv, 6/10kv, 8.7/10kv, 8.7/15kv, 12/20kv, 21/35kv, 26/35kv</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Maximale Leiter Temperatur: unter normalen(90<span style="color: #333333">U. Grad; c</span>), notfall(130<span style="color: #333333">U. Grad; c</span>) oder Kurzschluss nicht mehr als 5 s(250<span style="color: #333333">U. Grad; c</span>) Bedingungen.</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Min. Umgebungstemperatur.</span><span style="font-family: arial;color: #333333;font-size: 10.0pt">0 u. Grad; c, nach der Installation und nur, wenn Kabel ist in einer festen Position</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">Min. Biegeradius: 20 x kabel o. D f&uuml;r einzelne- Kern nicht- armierte kabel</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">15 x kabel o. D f&uuml;r einzelne- Kern armierte kabel</span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></strong><span style="font-family: arial;color: #333333;font-size: 10.0pt">15 x kabel o. D f&uuml;r multi- Kern nicht- armierte kabel</span></p>
<p align="left"><span style="font-family: arial;color: #333333;font-size: 10.0pt">12 x kabel o. D f&uuml;r multi- Kern armierte kabel</span></p>
</div>
<p><span style="font-family: arial;color: #231f20;font-size: 10.0pt">&nbsp;</span></p>
<p align="left"><strong><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Standards</span></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">Internationalen: iec 60502- 2, iec 60228</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">china</span><span style="font-family: arial;color: #231f20;font-size: 10.0pt">: gb/t 12706.2-2008</span></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt">andere Standards wie</span><span style="font-family: arial;color: #333333;font-size: 10.0pt">Bs, din und ICEA auf Anfrage</span><strong></strong></p>
<p align="left"><span style="font-family: arial;color: #231f20;font-size: 10.0pt"></span></p>
<p align="left"><strong><span style="font-family: arial;color: #333333;font-size: 10.0pt"><br />Spezifikationen</span></strong></p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 33.0pt" align="left">
<td style="width: 36.8pt">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">yjv</span></p>
</td>
<td style="width: 175.2pt;background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Kupferleiter, vpe-isolierte, pvc-ummantelte stromkabel</span></p>
</td>
<td style="width: 220.3pt;background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">F&uuml;r die Verlegung drinnen und drau&szlig;en. K&ouml;nnen tragen bestimmte Traktion w&auml;hrend der Installation, aber nicht externe mechanische Kr&auml;fte. Verlegung aderleitung in magnetischen Kan&auml;le ist nicht erlaubt.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">yjlv</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Leiter, vpe-isolierte, pvc-ummantelte stromkabel</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">yjy</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Kupferleiter, vpe-isolierte, pe-ummantelte stromkabel</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">F&uuml;r die Verlegung drinnen und drau&szlig;en. K&ouml;nnen tragen bestimmte Traktion w&auml;hrend der Installation, aber nicht externe mechanische Kr&auml;fte. Verlegung aderleitung in magnetischen Kan&auml;le ist nicht erlaubt.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">yjly</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Leiter, vpe-isolierte, pe-ummantelte stromkabel</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">yjv22</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Vpe-isolierte, stahlband gepanzerten, pvc-ummantelte stromkabel</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Geeignet zum Vergraben in boden, k&ouml;nnen tragen externe mechanische Kr&auml;fte aber gro&szlig;e Zugkr&auml;fte.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">yjlv22</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Isoliert, stahlband gepanzerten, pvc-ummantelte stromkabel</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">yjv32</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Kupferleiter, vpe-isolierte, feinen stahldraht gepanzerten, pvc-ummantelte stromkabel</span></p>
</td>
<td style="background: white;height: 33.0pt" rowspan="2">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Gelten f&uuml;r Wellen, Wasser und Boden, k&ouml;nnen tragen die gr&ouml;&szlig;ere &Uuml;berdruck.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">yjlv32</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Leiter, vpe-isolierte, feinen stahldraht gepanzerten, pvc-ummantelte stromkabel</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">yjv42</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Kupferleiter, vpe-isolierte, dicken stahldraht gepanzertes, pvc-ummantelte stromkabel</span></p>
</td>
<td style="height: 33.0pt" rowspan="2">
<p><span style="font-family: arial;color: black;font-size: 10.0pt">F&uuml;r die Verlegung in welle, Wasser unterirdisch und gro&szlig;e diference der Stufe, k&ouml;nnen tragen externe mechanischen druck und moderate Zugkraft.</span></p>
</td>
</tr>
<tr style="height: 33.0pt" align="left">
<td>
<p><span style="font-family: arial;color: black;font-size: 10.0pt">yjlv42</span></p>
</td>
<td style="background: white">
<p style="background: white"><span style="font-family: arial;background: white;color: black;font-size: 10.0pt">Al. Leiter, vpe-isolierte, dicken stahldraht gepanzertes, pvc-ummantelte stromkabel</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-family: arial;font-size: 10.0pt">&nbsp;</span></p>
<p><span style="line-height: 17.6px"><strong><span style="line-height: 19.0px;color: #333333">Zertifikate</span></strong>&nbsp;</span></p>
<p>&nbsp;</p>
<p align="left"><span style="line-height: 17.6px"><span style="line-height: 19.0px;color: #333333">Ce, rohs, ccc, KEMA und andere auf Anfrage</span><span style="line-height: 18.0px">&nbsp;</span></span><span style="line-height: 17.6px;font-family: verdana , arial , helvetica , sans-serif">&nbsp;</span></p>
<p>&nbsp;</p>
<p align="left">
<p>&nbsp;</p>
</p>
<p>&nbsp;</p>
<p align="left" style="border: 0.0px;vertical-align: baseline;color: #333333;font-family: arial , helvetica;line-height: 18.0px"><span style="line-height: 20.0px;font-size: 16.0px;font-family: calibri , zapf dingbats"><strong><span style="line-height: 19.0px">produktlinie</span></strong></span></p>
<p>&nbsp;</p>
<p align="left">
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p align="left"><span style="line-height: 20.0px;font-size: 16.0px;font-family: calibri , zapf dingbats"><strong>Firmenpr&auml;sentation</strong></span><span style="line-height: 17.6px;font-family: verdana , arial , helvetica , sans-serif">&nbsp;</span></p>
<p>&nbsp;</p>
<p align="left">
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p align="left">
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p align="left">
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="line-height: normal;font-size: inherit;font-style: inherit;font-weight: inherit;background-color: #ffff99;color: #333333">Sich bitte an pls!</span></p>
<p>&nbsp;</p>
<p>&nbsp;<span style="line-height: 15.0px;color: #333333;font-family: arial , helvetica">&nbsp;</span></p>
<p><span style="line-height: 20.0px;font-family: calibri , zapf dingbats;font-size: 14.0px;font-style: inherit;font-weight: inherit;color: #333333">Liebe Freunde, willkommen zu unserem Speicher.</span><span style="font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px">&nbsp;</span></p>
<p>&nbsp;</p>
<p><span style="line-height: 20.0px;font-family: calibri , zapf dingbats;font-size: 14.0px;font-style: inherit;font-weight: inherit;color: #333333">Wir sind ein f&uuml;hrender Hersteller von Dr&auml;hten&amp; kabel in china und sind spezialisiert auf das Feld f&uuml;r mehr als 20 Jahren, haben 21-kabel Fabriken, die auszugeben 1100000 km/Jahr, mit der St&auml;rke der Strom/control/Haus Verdrahtung/flexible feuerfeste/Instrumentierung/Zweig/spezialkabel ect, k&ouml;nnen Sie gute kabel mit Qualit&auml;t gew&auml;hrleistet&amp; preis angemessen!</span><span style="line-height: 17.272726px;font-family: verdana , arial , helvetica , sans-serif;font-size: 12.0px">&nbsp;</span></p>
<p>&nbsp;</p>
<p style="color: #333333;font-family: arial , helvetica;border: 0.0px;line-height: 15.0px;vertical-align: baseline"><span style="line-height: 20.0px;margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 14.0px;font-style: inherit;font-weight: inherit;vertical-align: baseline;font-family: calibri , zapf dingbats">Bitte kontaktieren Sie uns wenn der Fragen, Ihre professionelle kabel anbieter ist hier!</span></p>
<p style="color: #333333;font-family: arial , helvetica;border: 0.0px;line-height: 15.0px;vertical-align: baseline">&nbsp;</p>
<p>&nbsp;</p>
<div style="color: #333333;margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial;font-size: 10.0pt;line-height: 15.0px;vertical-align: baseline">
<div style="font-size: 10.0pt"><span style="line-height: 24.545454px;font-size: medium"><span style="line-height: 24.545454px;font-family: calibri">ada zhen</span></span></div>
<div style="font-size: 10.0pt"><span style="line-height: 35.454544px;color: #004080;font-family: calibri;font-size: x-large"><strong>shanghai shenghua kabel gruppe</strong></span></div>
</div>
<p>&nbsp;</p>
<div style="color: #333333;margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: verdana;line-height: 15.0px;vertical-align: baseline">
<p><span style="line-height: normal;font-size: 10.0pt;font-family: calibri">Viber( whatsapp): 86 188 1655 0573</span></p>
<p><span style="line-height: normal;font-size: 10.0pt;font-family: calibri">Skype: adazhen189</span></p>
<p><span style="line-height: normal;font-size: 10.0pt;font-family: calibri">Qq: 729689212</span></p>
</div>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/cu-xlpe-pvc-electric-cable-11kv-33kv-150-185-240-300-copper-wire-screened-mv-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
