<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>3*95+2*50 cable &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/395250-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Fri, 06 Sep 2019 07:59:22 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>3*95+2*50 cable XLPE  insulated  pvc jacket copper cable</title>
		<link>https://german.baoliyy.com/395250-cable-xlpe-insulated-pvc-jacket-copper-cable/</link>
				<comments>https://german.baoliyy.com/395250-cable-xlpe-insulated-pvc-jacket-copper-cable/#respond</comments>
				<pubDate>Fri, 06 Sep 2019 07:59:22 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[zzhd]]></category>
		<category><![CDATA[3*95+2*50 cable]]></category>
		<category><![CDATA[XLPE insualted pvc jacket copper cable]]></category>
		<category><![CDATA[yjv cable]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/395250-cable-xlpe-insulated-pvc-jacket-copper-cable/</guid>
				<description><![CDATA[unsere firma ist ein professioneller hersteller von 3*95 + 2*50 kabel&#160;. wir haben den besten R &#38; D, produktion, vertrieb und service-team und moderne enterprise-management-organisation. &#160; anwendung:SWA BS 5467 Kabel-power und hilfs f&#252;r den einsatz in stromnetzen, unterirdischen, au&#223;en-und innenbereich und f&#252;r den einsatz in kabelf&#252;hrung. Standards:BS5467, IEC 60502, BSEN (IEC) 60332-1-2 leiter:klasse 2 gestrandet [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p style="text-align: left">unsere firma ist ein professioneller hersteller von 3*95 + 2*50 kabel<span style="font-family: arial"><span style="line-height: 17.333334px">&nbsp;</span></span>. wir haben den besten R &amp; D, produktion, vertrieb und service-team und moderne enterprise-management-organisation.</p>
<p align="left">&nbsp;</p>
<p style="padding-bottom: 15.0px;border: 0.0px;vertical-align: baseline;background-color: transparent;color: #6d6e71;font-family: arial , helvetica , sans-serif;text-align: left"><strong>anwendung:</strong>SWA BS 5467 Kabel-power und hilfs f&uuml;r den einsatz in stromnetzen, unterirdischen, au&szlig;en-und innenbereich und f&uuml;r den einsatz in kabelf&uuml;hrung.</p>
<p style="padding-bottom: 15.0px;border: 0.0px;vertical-align: baseline;background-color: transparent;color: #6d6e71;font-family: arial , helvetica , sans-serif;text-align: left"><strong>Standards:</strong>BS5467, IEC 60502, BSEN (IEC) 60332-1-2</p>
<p style="padding-bottom: 15.0px;border: 0.0px;vertical-align: baseline;background-color: transparent;color: #6d6e71;font-family: arial , helvetica , sans-serif;text-align: left"><strong>leiter:</strong>klasse 2 gestrandet plain kupferleiter nach BS EN 60228: 2005 (zuvor BS6360)</p>
<p style="padding-bottom: 15.0px;border: 0.0px;vertical-align: baseline;background-color: transparent;color: #6d6e71;font-family: arial , helvetica , sans-serif;text-align: left"><strong>isolierung:</strong>VPE (Vernetztes Polyethylen)</p>
<p style="padding-bottom: 15.0px;border: 0.0px;vertical-align: baseline;background-color: transparent;color: #6d6e71;font-family: arial , helvetica , sans-serif;text-align: left"><strong>bettw&auml;sche:</strong>PVC (Polyvinylchlorid)</p>
<p style="padding-bottom: 15.0px;border: 0.0px;vertical-align: baseline;background-color: transparent;color: #6d6e71;font-family: arial , helvetica , sans-serif;text-align: left"><strong>armierung:</strong>&nbsp;<br />Single-Core: AWA (Aluminiumdraht Armour)<br />Multi Core: SWA (Stahldraht R&uuml;stung)</p>
<p style="padding-bottom: 15.0px;border: 0.0px;vertical-align: baseline;background-color: transparent;color: #6d6e71;font-family: arial , helvetica , sans-serif;text-align: left"><strong>mantel:</strong>PVC (Polyvinylchlorid)</p>
<p style="padding-bottom: 15.0px;border: 0.0px;vertical-align: baseline;background-color: transparent;color: #6d6e71;font-family: arial , helvetica , sans-serif;text-align: left"><strong>mantel Farbe:</strong>schwarz (Carbon geladen f&uuml;r UV stabilit&auml;t)</p>
<p style="padding-bottom: 15.0px;border: 0.0px;vertical-align: baseline;background-color: transparent;color: #6d6e71;font-family: arial , helvetica , sans-serif;text-align: left"><strong>Nennspannung:</strong>600/1000 V</p>
<p style="padding-bottom: 15.0px;border: 0.0px;vertical-align: baseline;background-color: transparent;color: #6d6e71;font-family: arial , helvetica , sans-serif;text-align: left"><strong>Temperaturbereich:</strong>0 &deg; C bis + 90 &deg; C</p>
<p style="padding-bottom: 15.0px;border: 0.0px;vertical-align: baseline;background-color: transparent;color: #6d6e71;font-family: arial , helvetica , sans-serif;text-align: left"><strong>Mindestbiegeradius:</strong>&nbsp;<br />1.5mm &sup2;-16mm&sup2;<br />6 x gesamtdurchmesser</p>
<p>25mm&sup2; und oben:<br />8 x gesamtdurchmesser</p>
<p style="padding-bottom: 15.0px;border: 0.0px;vertical-align: baseline;background-color: transparent;color: #6d6e71;font-family: arial , helvetica , sans-serif;text-align: left"><strong>Aderkennzeichnung:</strong>&nbsp;<br />1 Kern: Braun<br />2 Kerne: Braun, blau<br />3 Kerne: Braun, schwarz, grau<br />4 Kerne: Blau, braun, schwarz, grau<br />5 Kerne: Gr&uuml;n/Gelb, blau, braun, schwarz, grau<br />alternativen aderkennzeichnung: Wei&szlig; Kerne mit Schwarzen zahlen</p>
<div style="overflow:auto"><table border="0" cellpadding="0">
<tbody>
<tr>
<td colspan="4">
<p align="left"><strong>VPE-KABEL &#039;S ART UND HAUPTANWENDUNG</strong></p>
</td>
</tr>
<tr>
<td colspan="2">
<p align="left"><strong>TYP</strong></p>
</td>
<td rowspan="2">
<p align="left"><strong>beschreibung</strong></p>
</td>
<td rowspan="2">
<p align="left"><strong>Hauptanwendung</strong></p>
</td>
</tr>
<tr>
<td>
<p align="left"><strong>CU</strong>&nbsp;</p>
</td>
<td>
<p align="left"><strong>AI CORE</strong>&nbsp;</p>
</td>
</tr>
<tr>
<td>
<p align="left">YJV</p>
<p align="left">oder YJY</p>
</td>
<td>
<p align="left">YJLV</p>
<p align="left">oder YJLY</p>
</td>
<td>
<p align="left">vpe-isolierte,</p>
<p align="left">PVC oder PE mantel netzkabel</p>
</td>
<td>
<p align="left">gelten f&uuml;r die verlegung im innenbereich,</p>
<p align="left">in tunnels und kabel graben.</p>
<p align="left">nicht zu tragen externe mechanische kr&auml;fte.</p>
<p align="left">single-core-kabel in magnetische kanal ist nicht zul&auml;ssige.</p>
</td>
</tr>
<tr>
<td>
<p align="left">YJV22</p>
<p align="left">oder YJY23</p>
</td>
<td>
<p align="left">YJLV22</p>
<p align="left">oder YJLY23</p>
</td>
<td>
<p align="left">vpe-isolierte,</p>
<p align="left">stahlband gepanzerten, PVC oder PE mantel netzkabel</p>
</td>
<td>
<p align="left">gelten f&uuml;r die verlegung im innenbereich,</p>
<p align="left">in tunnels, kabel graben und direkt im boden.</p>
<p align="left">in der lage zu tragen externe mechanische kr&auml;fte,</p>
<p align="left">aber nicht zu tragen gro&szlig;e zugkr&auml;fte.</p>
<p align="left">&nbsp;</p>
</td>
</tr>
<tr>
<td>
<p align="left">YLV32</p>
<p align="left">oder YJV33</p>
</td>
<td>
<p align="left">YJLV</p>
<p align="left">oder YJLY 33</p>
</td>
<td>
<p align="left">vpe-isolierte</p>
<p align="left">feinen stahldraht gepanzerten, PVC oder PE mantel netzkabel</p>
</td>
<td>
<p align="left">gelten f&uuml;r die verlegung im innenbereich,</p>
<p align="left">in tunnels, kabel graben und direkt im boden.</p>
<p align="left">in der lage zu tragen externe machanical kraft</p>
<p align="left">und moderate zugkraft</p>
</td>
</tr>
<tr>
<td>
<p align="left">YJV42</p>
<p align="left">oder YJV43</p>
</td>
<td>
<p align="left">YJLV42</p>
<p align="left">oder YJLV43</p>
</td>
<td>
<p align="left">vpe-isolierte,</p>
<p align="left">dicken stahldraht gepanzerten,</p>
<p align="left">PVC oder PE mantel netzkabel</p>
</td>
<td>
<p align="left">gelten f&uuml;r die verlegung in wasser und meeresboden.</p>
<p align="left">in der lage zu tragen possitive druck und zugkraft</p>
</td>
</tr>
</tbody>
</table></div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/395250-cable-xlpe-insulated-pvc-jacket-copper-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>