<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>3&#215;50 XLPE cable aluminum \/ copper insulation &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/3x50-xlpe-cable-aluminum-copper-insulation/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Wed, 11 Sep 2019 04:41:11 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.26</generator>
	<item>
		<title>IEC standard XLPE insulated copper cable 3x95sqmm</title>
		<link>https://german.baoliyy.com/iec-standard-xlpe-insulated-copper-cable-3x95sqmm/</link>
				<comments>https://german.baoliyy.com/iec-standard-xlpe-insulated-copper-cable-3x95sqmm/#respond</comments>
				<pubDate>Wed, 11 Sep 2019 04:41:11 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[jinshui]]></category>
		<category><![CDATA[11KV XLPE insulated STA armored power cable]]></category>
		<category><![CDATA[1KV underground XLPE cable 4x25mm]]></category>
		<category><![CDATA[3x50 XLPE cable aluminum \/ copper insulation]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/iec-standard-xlpe-insulated-copper-cable-3x95sqmm/</guid>
				<description><![CDATA[anwendung: es wird verwendet, um und verteilen power in energie&#252;bertragung und-verteilung system von 35kV oder niedriger. es ist in der regel angewendet, um den bereichen einschlie&#223;lich, bau, minen, metallurgie, petrochemie und kommunikation in komplette ersetzen von &#246;lbad papier isolierte kabel und in teil ersetzen von pvc-isolierte stromkabel kabel. konstruktion: leiter: Kupfer (oder Aluminium) isolierung: XLPE [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<h5><strong><span style="font-size: 14.0px">anwendung:</span></strong></h5>
<h5><strong></strong><br /><span style="font-size: 12.0px">es wird verwendet, um und verteilen power in energie&uuml;bertragung und-verteilung system von 35kV oder niedriger. es ist in der regel angewendet, um den bereichen einschlie&szlig;lich, bau, minen, metallurgie, petrochemie und kommunikation in komplette ersetzen von &ouml;lbad papier isolierte kabel und in teil ersetzen von pvc-isolierte stromkabel kabel.</span></h5>
<h5><span style="font-size: 14.0px">konstruktion:</span></h5>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>leiter: Kupfer (oder Aluminium)</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>isolierung: XLPE</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>f&uuml;llstoff: Nicht hygroskopisch Polypropylen (PP)</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Binder Band: vliesstoff</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>innere Abdeckung: PVC</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Metallic R&uuml;stung: Verzinktem Stahldraht R&uuml;stung (SWA)</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>nicht magnetische Stahldraht R&uuml;stung (nur f&uuml;r single-core)</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Aluminiumdraht Gepanzerten (AWA, nur f&uuml;r single-core)</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Outer Mantel: PVC (oder PE)</strong></span></p>
<h5><span style="font-size: 14.0px">Standards:</span></h5>
<h5><span style="font-size: 12.0px">die produkte werden haupts&auml;chlich einhaltung mit IEC 60502 standard, k&ouml;nnen auch nach OEM anforderungen und andere standards, wie BS standard, DIN-norm, ASTM standard, etc.</span><br /><span style="font-size: 12.0px">spannung grade ist bis zu 35kv, querschnitt bereich kann bis zu 400 mm&sup2; (kupfer oder alumimum leiter). leiter langen temperatur ist 90 &deg; C. In kurzschluss, leiter h&ouml;chste temperatur sollte nicht mehr als 250 &deg; C</span></p>
</h5>
<h5><strong><span style="font-size: 14.0px">mit features:</span></strong></p>
<p><span style="font-size: 12.0px">1. nennspannung: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8,7/10kV, 8,7/15kV, 6/6kV, 6/10kV.</span><br /><span style="font-size: 12.0px">2. No. von core: Single-core, drei-core.</span><br /><span style="font-size: 12.0px">3. Die h&ouml;chsten erlaubt betriebstemperatur des leiters f&uuml;r langfristige arbeits ist 90 &deg; C. In kurzschluss (Max. Langfristige ist nicht mehr als 5 sekunden). die h&ouml;chste temperatur f&uuml;r leiter ist nicht mehr als 250 &deg; C.</span><br /><span style="font-size: 12.0px">4. D.C Widerstand des leiters entspricht den regelungen GB/T3956-1997.</span><br /><span style="font-size: 12.0px">5. Die umgebungstemperatur sollte nicht niedriger als 0 &deg; C, wenn legen. andernfalls es sollte vorgew&auml;rmt.</span><br /><span style="font-size: 12.0px">6. Das kabel ist gelegt ohne horizontale drop grenze. die Min. biegeradius von drei-core kabel sollte nicht kleiner als 12 mal der kabelau&szlig;endurchmesser durchmesser.</span><br /><span style="font-size: 12.0px">7. Arbeitsfrequenz Spannungspr&uuml;fung:.</span><br /><span style="font-size: 12.0px">f&uuml;r kabel mit Uo von 3.6kV oder niedriger: 2.5Uo + 2kV/5 min ohne punktion.</span><br /><span style="font-size: 12.0px">f&uuml;r kabel mit Uo von 3.6Kv ~ 18kV: 3.5Uo/5 min ohne punktion.</span><br /><span style="font-size: 12.0px">f&uuml;r kabel mit Uo von 21kV und 26 kV: 2.5Uo/30 min ohne punktion.</span><br /><span style="font-size: 12.0px">8. Teilentladung Test: Die entladung volumen sollte nicht mehr als 10 st&uuml;ck unter 1.73Uo f&uuml;r die kabel.</span></h5>
<div style="overflow:auto"><table style="line-height: 18.0px;width: 652.0px;font-family: arial , helvetica , sans-serif;color: #333333;font-size: 12.0px" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 29.25pt" align="middle">
<td style="margin: 0.0px;width: 3.0cm">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">typ</span></p>
</td>
<td style="margin: 0.0px;width: 9.0cm">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">beschreibung</span></p>
</td>
<td style="margin: 0.0px;width: 70.9pt">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">anzahl der</span></p>
</td>
<td style="margin: 0.0px;width: 77.95pt">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">nenn querschnitt des leiters</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA/PVC Stromkabel</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJLV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA/PVC Stromkabel</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJV72</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/nicht-magnetische SWA oder AWA/PVC Stromkabel</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJLV72</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/nicht-magnetische SWA oder AWA/PVC Stromkabel</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJV33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA/PE Stromkabel</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJLV33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA/PE Stromkabel</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Z-YJV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA flammschutzmittel Netzkabel</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Z-YJLV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA flammschutzmittel Netzkabel</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">WDZ-YJY33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA Low Smoke Halogen Free oder Zero Halogen (LSHF oder LSZH) flammhemmende Stromkabel</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">WDZ-YJLY33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA Low Smoke Halogen Free oder Zero Halogen (LSHF oder LSZH) flammhemmende Stromkabel</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">N-YJV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA Feuer-hitzebest&auml;ndigen Stromkabel</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div style="overflow:auto"><table style="margin-left: auto;margin-right: auto" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="middle">
<td style="width: 122.4pt" colspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">typ</span></p>
</td>
<td style="width: 108.0pt" rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Name</span></p>
</td>
<td style="width: 195.7pt" rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">anwendung</span></p>
</td>
</tr>
<tr align="middle">
<td style="width: 59.4pt">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Cu</span></p>
<p align="center"><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">conducto</span></p>
</td>
<td style="width: 63.0pt">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Al</span></p>
<p align="center"><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">leiter</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">vpe-isolierte, PVC oder PE ummantelte stromkabel</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">f&uuml;r legen innen, tunnel, kanal und unterirdischen. nicht zu tragen externe mechanische kraft w&auml;hrend gelegt.</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJY</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium"><span style="font-size: large">22</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV<sub><span style="font-size: medium"><span style="font-size: large">22</span></span></sub></span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">vpe-isolierte, stahlband gepanzerten, PVC oder PE ummantelte stromkabel</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">f&uuml;r legen innen, tunnel, kanal und unterirdischen. in der lage zu tragen externe mechanische kraft, aber nicht gro&szlig;e zugkraft zu tragen.</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium"><span style="font-size: large">23</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLY<span style="font-size: medium"><span style="font-size: large"><sub>2</sub><sub>3</sub></span></span></span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium"><span style="font-size: large">32</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV<sub><span style="font-size: medium"><span style="font-size: large">32</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">vpe-isolierte, feinen stahldraht gepanzerten, PVC oder PE ummantelte stromkabel</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">f&uuml;r die verlegung in welle mit gro&szlig;en h&ouml;henunterschied. in der lage zu tragen externe mechanische kraft, und moderate zugkraft.</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium"><span style="font-size: large">42</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV<sub><span style="font-size: medium"><span style="font-size: large">42</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">vpe-isolierte, dicken stahl gepanzerte, PVC oder PE ummantelte stromkabel</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">f&uuml;r die verlegung in welle mit gro&szlig;en h&ouml;henunterschied. in der lage zu tragen externe mechanische kraft, und moderate zugkraft.</span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/iec-standard-xlpe-insulated-copper-cable-3x95sqmm/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
