<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Aluminium cable xlpe insulation power cable &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/aluminium-cable-xlpe-insulation-power-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Tue, 21 Jun 2022 00:16:21 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.27</generator>
	<item>
		<title>Medium Voltage 8.7/15KV 3C*185mm Aluminium cable xlpe insulation power cable</title>
		<link>https://german.baoliyy.com/medium-voltage-8-7-15kv-3c185mm-aluminium-cable-xlpe-insulation-power-cable/</link>
				<comments>https://german.baoliyy.com/medium-voltage-8-7-15kv-3c185mm-aluminium-cable-xlpe-insulation-power-cable/#respond</comments>
				<pubDate>Tue, 21 Jun 2022 00:16:21 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[sonorouscable]]></category>
		<category><![CDATA[3C*185mm Aluminium cable]]></category>
		<category><![CDATA[Aluminium cable xlpe insulation power cable]]></category>
		<category><![CDATA[XLPE insulation aluminium power cable]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/medium-voltage-8-7-15kv-3c185mm-aluminium-cable-xlpe-insulation-power-cable/</guid>
				<description><![CDATA[8.7/15kv 3c*185mm aluminium vpe-isolierung stromkabel &#160; &#160; Produktbeschreibung 8.7/15kv3 adernstromkabel 3c*185mm aluminiumleiter Aluminium vpe-isolierung stromkabel &#160; &#160; Vpe-isolierung pvc-mantelswa oder sta gepanzertenStandard: iec60502, gb/t 12706 &#160; &#160; Art von aluminium vpe-isolierte stromkabel: Cu oder im/vpe/CTS oder cws/pvc netzkabel Cu oder im/vpe/CTS oder cws/PVC/SWA/pvc netzkabel &#160; &#160; &#160; &#160; &#160; &#160; &#160; &#160; Anwendung von 8.7/15kv [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><span style="font-size: 16.0px;background-color: #00ff00"><strong>8.7/15kv 3c*185mm aluminium vpe-isolierung stromkabel</strong></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-f37yf" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-f37yf" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Produktbeschreibung</span></div>
<div style="padding: 10.0px 0">
<p><span style="background-color: #ffffff;line-height: 21.0px;font-size: 14.0px;font-family: verdana , arial , helvetica , sans-serif">8.7/15kv</span><span style="color: #333333"><span style="line-height: 15.0px">3 adern</span></span><span style="background-color: #ffffff;line-height: 21.0px;font-size: 14.0px;font-family: verdana , arial , helvetica , sans-serif">stromkabel</span></p>
</div>
</div>
<p><span style="font-size: 14.0px">3c*185mm aluminiumleiter</span></p>
<p><span style="font-size: 14.0px">Aluminium vpe-isolierung stromkabel</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: 14.0px">Vpe-isolierung pvc-mantel</span><br /><span style="font-size: 14.0px">swa oder sta gepanzerten</span><br /><span style="font-size: 14.0px">Standard: iec60502, gb/t 12706</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="color: #333333;font-family: arial , helvetica , sans-serif;font-size: 14.0px"><span style="line-height: 15.0px">Art von aluminium vpe-isolierte stromkabel:</span></span></strong></p>
<p align="left"><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , sans-serif">Cu oder im/vpe/CTS oder cws/pvc netzkabel</span></p>
<p align="left"><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , sans-serif">Cu oder im/vpe/CTS oder cws/PVC/SWA/pvc netzkabel</span></p>
<p align="left">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="color: #333333;font-family: arial , helvetica , sans-serif;font-size: 14.0px"><span style="line-height: 15.0px"><span style="font-style: normal;line-height: normal">Anwendung von 8.7/15kv 3c*185mm aluminium vpe-isolierung stromkabel:</span></span></span></strong></p>
<p><strong></strong><span style="font-size: 14.0px"><span style="line-height: normal;font-family: arial , sans-serif">Das Produkt ist geeignet f&uuml;r den Einsatz in energie&uuml;bertragung und-verteilung Linien mit Nennleistung frequenz 3.6/6kv</span><span style="font-family: verdana , arial , helvetica , sans-serif;line-height: normal">~</span><span style="line-height: normal;font-family: arial , sans-serif">26/35kv.</span><span style="line-height: normal;font-family: arial , sans-serif">F&uuml;r die Verlegung drinnen, im Tunnel, kabel graben, gut oder direkt in Boden.</span><span style="line-height: 18.0px;font-family: verdana , arial , helvetica , sans-serif">&nbsp;</span></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="color: #333333;font-family: arial , helvetica , sans-serif;font-size: 14.0px"><span style="line-height: 15.0px"><span style="font-style: normal;line-height: normal"><span style="font-style: normal;line-height: normal;font-family: arial , sans-serif">Merkmal 8.7/15kv 3c*185mm aluminium vpe-isolierung stromkabel:</span></span></span></span></strong></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">1. die h&ouml;chste erlaubt Betriebstemperatur von Leiter f&uuml;r Langzeit- arbeiten 90 Grad.</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">2. in Kurzschluss( max langfristig ist nicht mehr als 5 Sekunden). Die h&ouml;chste Temperatur f&uuml;r leiter ist nicht mehr als 250 Grad.</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">3. das Kabel gelegt ohne horizontale drop Grenze. Die Umwelt Temperatur sollte nicht niedriger als 0, wenn legen. Sonst sollte vorgeheizten.</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">4. ausgezeichnete elektrische leistung, Best&auml;ndigkeit gegen chemische Korrosion.</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">5. stehen kann ratsam Traktion beim gelegt. Stehen kann Traktion von au&szlig;erhalb. Links low smoke halogen- frei nach verbrannt. Verz&ouml;gern die Verbrennung des Kabels.</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px"><strong><span style="color: #333333">Geringe kreuz- Schnitt Bereichen:</span></strong></span></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">1. 5 mm 2,2. 5 mm 2,4 mm 2,6 mm 2,10 mm 2,16 mm 2,25 mm 2,35 mm 2,50 mm 2,70 mm 2,95 mm 2,120 mm 2,150 mm 2,185 mm 2,240 mm 2,300 mm 2,400 mm 2,500 mm 2,630 mm 2,800 mm2</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px"><strong><span style="color: #333333">Produktpalette:</span></strong></span></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">Aderleitung: von 1,5 mm2 bis 800 mm 2,</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">Multi- adriges kabel: von 1,5 mm2 bis 400 mm2</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px"><span style="font-style: normal;line-height: normal">Spezifikation von vpe-isolierung stromkabel:</span></span></strong></p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="left">
<td colspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Leiter</span></p>
</td>
<td rowspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Struktur</span></p>
</td>
<td rowspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Anwendung</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">cu</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">al</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjv</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjlv</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Vpe-isolierung pvc netzkabel( Cu/vpe/PVC)</span></p>
</td>
<td rowspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Verlegt werden drinnen, im Tunnel, kabel Furche oder Rohr, das Kabel konnte nicht tragen mechanische Kraft au&szlig;erhalb</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjy</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjly</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Vpe-isolierung pe-mantel netzkabel( Cu/vpe/pe)</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjv22</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjlv22</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Vpe-isolierung, stahlband r&uuml;stung, pvc netzkabel</span></p>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">( Cu/vpe/PVC/sta/PVC)</span></p>
</td>
<td rowspan="3">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Verlegt werden unterirdischen, das Kabel ertragen konnte bestimmte mechanische Kraft, aber es konnte nicht tragen gro&szlig;e Zugkraft.</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjv23</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjlv23</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Vpe-isolierung, stahlband r&uuml;stung, pe-mantel netzkabel</span></p>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">( Cu/vpe/PVC/sta/pe)</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjv62</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjlv62</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Vpe-isolierung, keine magnetismus stahlband r&uuml;stung, pe-mantel netzkabel</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjv32</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjlv32</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Vpe-isolierung, d&uuml;nne Stahl- r&uuml;stung draht, pvc netzkabel</span></p>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">( Cu/vpe/PVC/SWA/PVC)</span></p>
</td>
<td rowspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">F&uuml;r die gut, Wasser in und R&uuml;ckgang der Bad boden, das Kabel dosen tragen die gleichen Kraft au&szlig;erhalb der maschine mit ziehen die Kraft</span></p>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">.</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjv72</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjlv72</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Vpe-isolierung, haben keine der Magnetismus dickem stahl- r&uuml;stung draht, pvc netzkabel</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjv42</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">yjlv42</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Vpe-isolierung, dickem stahl- r&uuml;stung draht, pvc netzkabel</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">F&uuml;r die gut, unter wasser mit Ende Meer, das Kabel dosen tragen die gr&ouml;&szlig;er Druck mit f&uuml;hren, um die Pull Kraft.</span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: 14.0px;color: #000000"><strong>Einige Bilder unserer stromkabel:</strong></span></p>
<p><span style="font-size: 14.0px;color: #000000"><strong></strong></span></p>
<p><span style="font-size: 14.0px;color: #000000"><strong></strong></span></p>
<p><span style="font-size: 14.0px;color: #000000"><strong></strong></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-4m1l4" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-4m1l4" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">verpackung und Versand</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-q3ocr" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-q3ocr" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Unternehmensinformationen</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<p><strong></strong></p>
<p><strong></strong></p>
<p><strong></strong></p>
<p>&nbsp;</p>
<p><span style="font-size: 14.0px"><strong>Zertifikat:</strong></span></p>
<p><strong></strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-g1jsa" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-g1jsa" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">unsere Dienstleistungen</span></div>
<div style="padding: 10.0px 0">
<p><strong><span style="font-size: 14.0px">Kontakt:</span></strong></p>
</div>
</div>
<p style="border: 0.0px currentcolor;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><strong></strong><strong><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica , sans-serif;font-size: 14.0px;font-style: inherit;line-height: 24.0px;vertical-align: baseline;color: #008000">Ms. Echo</span></strong></p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><strong><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica , sans-serif;font-size: 14.0px;font-style: inherit;line-height: 24.0px;vertical-align: baseline;color: #008000">Handy: 0086-15106980528</span></strong></p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><strong><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica , sans-serif;font-size: 14.0px;font-style: inherit;line-height: 24.0px;vertical-align: baseline;color: #008000">Skype: hongliangcablesales7</span></strong></p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><strong><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica , sans-serif;font-size: 14.0px;font-style: inherit;line-height: 24.0px;vertical-align: baseline;color: #008000">Em: hongliangcable7( at) hldlcable. Com</span></strong></p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/medium-voltage-8-7-15kv-3c185mm-aluminium-cable-xlpe-insulation-power-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
