<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Aluminum \/ copper conductor XLPE cable &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/aluminum-copper-conductor-xlpe-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Wed, 11 Sep 2019 05:07:47 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.28</generator>
	<item>
		<title>LV XLPE insulated copper cable 4x95sqmm</title>
		<link>https://german.baoliyy.com/lv-xlpe-insulated-copper-cable-4x95sqmm/</link>
				<comments>https://german.baoliyy.com/lv-xlpe-insulated-copper-cable-4x95sqmm/#respond</comments>
				<pubDate>Wed, 11 Sep 2019 05:07:47 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[jinshui]]></category>
		<category><![CDATA[Aluminum \/ copper conductor XLPE cable]]></category>
		<category><![CDATA[IEC standard XLPE insulated armored cable 4x50sqmm]]></category>
		<category><![CDATA[mv xlpe power cable swa armor 3x185mm]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/lv-xlpe-insulated-copper-cable-4x95sqmm/</guid>
				<description><![CDATA[Produkt Beschreibung &#160;Anwendung: Es ist verwendet zu &#252;bertragen und verteilen power in power &#252;bertragung und verteilung system von 35kV oder niedriger. Es ist in der regel angewendet zu den bereichen einschlie&#223;lich power, bau, minen, metallurgie, petrochemie industrie und kommunikation in komplette ersetzen von &#246;l eingetaucht papier isolierte kabel und in teil ersetzen von PVC isolierte [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<div id="ali-anchor-AliPostDhMb-n3g1q" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-n3g1q" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Produkt Beschreibung</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;<strong><span style="font-size: 14.0px">Anwendung:</span></strong></p>
</div>
</div>
<h5><span style="font-size: 12.0px">Es ist verwendet zu &uuml;bertragen und verteilen power in power &uuml;bertragung und verteilung system von 35kV oder niedriger. Es ist in der regel angewendet zu den bereichen einschlie&szlig;lich power, bau, minen, metallurgie, petrochemie industrie und kommunikation in komplette ersetzen von &ouml;l eingetaucht papier isolierte kabel und in teil ersetzen von PVC isolierte kabel.</span></h5>
<h5><span style="font-size: 14.0px">Bau:</span></h5>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Leiter: Kupfer (oder Aluminium)</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Isolierung: XLPE</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>F&uuml;llstoff: Nicht hygroskopisch Polypropylen (PP)</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Binder Band: Nicht-gewebe</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Innere Abdeckung: PVC</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Metallic Armour: Verzinktem Stahl Draht Armour (SWA)</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Nicht-magnetische Stahl Draht Armour (nur f&uuml;r single-core)</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Aluminium Draht Armoured (AWA, nur f&uuml;r single-core)</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>&Auml;u&szlig;ere Mantel: PVC (oder PE)</strong></span></p>
<h5><span style="font-size: 14.0px">Standards:</span></h5>
<h5><span style="font-size: 12.0px">Die produkte sind vor allem einhaltung mit IEC 60502 standard, auch k&ouml;nnen nach hergestellt werden OEM anforderungen und andere standards, wie BS standard, DIN-norm, ASTM standard, etc.</span><br /><span style="font-size: 12.0px">Spannung grade ist bis zu 35kv, kreuz-abschnitt bereich kann bis zu 400 qmm (kupfer oder alumimum leiter). Leiter lange-zeit betriebs temperatur ist 90 &deg;C. In kurzschluss, leiter h&ouml;chste temperatur sollte nicht mehr als 250 &deg;C</span></p>
</h5>
<h5><strong><span style="font-size: 14.0px">Mit eigenschaften:</span></strong></p>
<p><span style="font-size: 12.0px">1. nennspannung: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8,7/10kV, 8,7/15kV, 6/6kV, 6/10kV.</span><br /><span style="font-size: 12.0px">2. keine. von core: Single-core, Drei-core.</span><br /><span style="font-size: 12.0px">3. die h&ouml;chste erlaubt betriebs temperatur des leiters f&uuml;r langfristige arbeits ist 90 &deg;C. In kurzschluss (Max. Langfristige ist keine mehr als 5 sekunden). Die h&ouml;chste temperatur f&uuml;r leiter ist keine mehr als 250 &deg;C.</span><br /><span style="font-size: 12.0px">4. D.C Widerstand der leiter entspricht mit den bestimmungen von GB/T3956-1997.</span><br /><span style="font-size: 12.0px">5. die umwelt temperatur sollte keine niedriger als 0 &deg;C wenn laien. Sonst sollte es vorgeheizt werden.</span><br /><span style="font-size: 12.0px">6. die kabel ist gelegt ohne horizontale drop grenze. Die Min. biegen radius von drei-core kabel sollte nicht kleiner als 12 mal von kabel &auml;u&szlig;ere durchmesser.</span><br /><span style="font-size: 12.0px">7. Working Frequenz Spannung Test:.</span><br /><span style="font-size: 12.0px">F&uuml;r kabel mit Uo von 3.6kV oder niedriger: 2.5Uo + 2kV/5 min ohne punktion.</span><br /><span style="font-size: 12.0px">F&uuml;r kabel mit Uo von 3.6Kv ~ 18kV: 3.5Uo/5 min ohne punktion.</span><br /><span style="font-size: 12.0px">F&uuml;r kabel mit Uo von 21kV und 26 kV: 2.5Uo/30 min ohne punktion.</span><br /><span style="font-size: 12.0px">8. teil Entladung Test: Die entladung volumen sollte nicht mehr als 10 pC unter 1.73Uo f&uuml;r die kabel.</span></h5>
<div style="overflow:auto"><table style="line-height: 18.0px;width: 652.0px;font-family: arial , helvetica , sans-serif;color: #333333;font-size: 12.0px" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 29.25pt" align="middle">
<td style="margin: 0.0px;width: 3.0cm">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Typ</span></p>
</td>
<td style="margin: 0.0px;width: 9.0cm">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Beschreibung</span></p>
</td>
<td style="margin: 0.0px;width: 70.9pt">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Anzahl der kerne</span></p>
</td>
<td style="margin: 0.0px;width: 77.95pt">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Nenn querschnitt des leiters</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA/PVC Power Kabel</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJLV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA/PVC Power Kabel</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJV72</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/Nicht-magnetische SWA oder AWA/PVC Power Kabel</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJLV72</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/Nicht-magnetische SWA oder AWA/PVC Power Kabel</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJV33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA/PE Power Kabel</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJLV33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA/PE Power Kabel</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Z-YJV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA Flamme-hemmende Power Kabel</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Z-YJLV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA Flamme-hemmende Power Kabel</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">WDZ-YJY33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA Niedrigen Rauch Halogen Freies oder Null Halogen (LSHF oder LSZH) flammhemmende Power Kabel</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">WDZ-YJLY33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA Niedrigen Rauch Halogen Freies oder Null Halogen (LSHF oder LSZH) flammhemmende Power Kabel</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">N-YJV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA Feuer-best&auml;ndig Power Kabel</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div style="overflow:auto"><table style="margin-left: auto;margin-right: auto" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="middle">
<td style="width: 122.4pt" colspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Typ</span></p>
</td>
<td style="width: 108.0pt" rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Name</span></p>
</td>
<td style="width: 195.7pt" rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Anwendung</span></p>
</td>
</tr>
<tr align="middle">
<td style="width: 59.4pt">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Cu</span></p>
<p align="center"><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Conducto</span></p>
</td>
<td style="width: 63.0pt">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Al</span></p>
<p align="center"><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Leiter</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Vpe-isolierte, PVC oder PE ummantelte stromkabel</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">F&uuml;r legen innen, tunnel, kanal und unterirdischen. Nicht in der lage zu tragen externe mechanische kraft w&auml;hrend gelegt.</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJY</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium"><span style="font-size: large">22</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV<sub><span style="font-size: medium"><span style="font-size: large">22</span></span></sub></span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Vpe-isolierte, stahl gepanzerten, PVC oder PE ummantelte stromkabel</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">F&uuml;r legen innen, tunnel, kanal und unterirdischen. In der lage zu tragen externe mechanische kraft, aber nicht in der lage zu tragen gro&szlig;e zugkraft.</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium"><span style="font-size: large">23</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLY<span style="font-size: medium"><span style="font-size: large"><sub>2</sub><sub>3</sub></span></span></span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium"><span style="font-size: large">32</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV<sub><span style="font-size: medium"><span style="font-size: large">32</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Vpe-isolierte, feinen stahldraht gepanzerten, PVC oder PE ummantelte stromkabel</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">F&uuml;r die verlegung in welle mit gro&szlig;er unterschied von ebene. In der lage zu tragen externe mechanische kraft, und moderate zugkraft.</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium"><span style="font-size: large">42</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV<sub><span style="font-size: medium"><span style="font-size: large">42</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Vpe-isolierte, starke stahl gepanzerte, PVC oder PE ummantelte stromkabel</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">F&uuml;r die verlegung in welle mit gro&szlig;er unterschied von ebene. In der lage zu tragen externe mechanische kraft, und moderate zugkraft.</span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-fe140" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-fe140" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Verwandte Produkt</span></div>
<div style="padding: 10.0px 0">
<div style="width: 750.0px;color: #000000;font-family: arial;margin: 0.0px auto;padding: 0.0px">
<p style="width: 750.0px;color: #000000;font-family: arial;margin: 0.0px auto;padding: 0.0px">&nbsp;</p>
<p style="margin-top: -50.0px">
<map name="Map">       </map>
</p>
</div>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-o6g9o" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-o6g9o" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Unternehmen Informationen</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-5dqqo" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-5dqqo" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Kunden</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-57v2j" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-57v2j" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Ausstellung</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-9vta2" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-9vta2" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">FAQ</span></div>
<div style="padding: 10.0px 0">
<p><strong>1. sind sie die fabrik oder handels unternehmen?</strong><br /><span style="color: #333333;font-family: arial;font-size: 16.0px;font-style: normal;font-weight: 400;background-color: #ffffff;float: none">Wir sind die hersteller und 13 jahre gold lieferant auf alibaba. wir sind in export kabel f&uuml;r fast 15 jahre.</span></p>
<p><strong>2. wenn kann ich die preis?</strong><br /><span style="color: #333333;font-family: arial;font-size: 16.0px;font-style: normal;font-weight: 400;background-color: #ffffff;float: none">Wir in der regel innerhalb von 6 stunden, nachdem wir ihre anfrage erhalten. Wenn sie sehr dringend erhalten die preis, bitte rufen sie uns oder sagen uns in ihre e-mail so, dass wir ihre anfrage priorit&auml;t betrachten.</span></p>
<p><strong>3. wie kann ich eine probe ihre qualit&auml;t zu &uuml;berpr&uuml;fen?</strong><br /><span style="color: #333333;font-family: arial;font-size: 16.0px;font-style: normal;font-weight: 400;background-color: #ffffff;float: none">Nach preis best&auml;tigung, sie erfordern k&ouml;nnen f&uuml;r proben unsere qualit&auml;t zu &uuml;berpr&uuml;fen. Probe ist frei, aber die freightcharge sollte bezahlt werden.</span></p>
<p><strong>4. was ist die zahlungsbedingungen?</strong><br /><span style="color: #333333;font-family: arial;font-size: 16.0px;font-style: normal;font-weight: 400;background-color: #ffffff;float: none">30% ablagerung durch T/T, 70% T/T nach &uuml;berpr&uuml;fung der kopie von B/L. Oder unwiderrufliches L/C am anblick.</span></p>
<p><strong>5. was &uuml;ber die blei zeit f&uuml;r massen produktion?</strong><br /><span style="color: #333333;font-family: arial;font-size: 16.0px;font-style: normal;font-weight: 400;background-color: #ffffff;float: none">Ehrlich gesagt, es h&auml;ngt von der bestellmenge und die saison sie die bestellung aufgeben. Generell, wir schlagen vor, dass sie anfrage starten zwei monate vor dem datum, das sie m&ouml;chten, um die produkte zu ihrem land.</span></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-t0o8z" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-t0o8z" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Kontaktieren sie Uns</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/lv-xlpe-insulated-copper-cable-4x95sqmm/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
