<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>AYCWY cable &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/aycwy-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Mon, 16 Sep 2019 08:01:36 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.27</generator>
	<item>
		<title>High Quality AYCWY cable XLPE Insulated Power Cable 0.6/1kv</title>
		<link>https://german.baoliyy.com/high-quality-aycwy-cable-xlpe-insulated-power-cable-0-6-1kv/</link>
				<comments>https://german.baoliyy.com/high-quality-aycwy-cable-xlpe-insulated-power-cable-0-6-1kv/#respond</comments>
				<pubDate>Mon, 16 Sep 2019 08:01:36 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[yifang]]></category>
		<category><![CDATA[AYCWY cable]]></category>
		<category><![CDATA[xlpe insulated power cable]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/high-quality-aycwy-cable-xlpe-insulated-power-cable-0-6-1kv/</guid>
				<description><![CDATA[Aycwy kabel vpe-isolierte stromkabel &#160;&#160; 1 &#160; Eine, Bau: Leiter: draht oder litze kupferIsolierung: Kreuz- verbunden Polyethylen( vpe) oder Polyvinylchlorid( PVC)F&#252;llstoff: polypropylen mit gel&#228;ppt bindebandBindemittel: bindebandInnenmantel: Polyvinylchlorid( PVC)Amour: verzinktem stahldraht gepanzertes( SWA) oder stahlband gepanzerten( sta)Mantel: Polyvinylchlorid( PVC) &#160; B, Funktionen &#160;Vpe-isolierte stromkabel nicht nur hat ausgezeichnete elektrische, mechanischen eigenschaften, aber hat auch starke Widerstand [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><strong><span style="color: #3366ff;font-size: 18.0px">Aycwy kabel vpe-isolierte stromkabel</span></strong></p>
<p><strong><span style="color: #3366ff;font-size: 18.0px">&nbsp;</span></strong><strong></strong>&nbsp;</p>
<p><strong><span style="font-size: 14.0pt">1</span></strong></p>
<p><strong></strong>&nbsp;</p>
<p><strong>Eine, Bau:</strong></p>
<p>Leiter: draht oder litze kupfer<br />Isolierung: Kreuz- verbunden Polyethylen( vpe) oder Polyvinylchlorid( PVC)<br />F&uuml;llstoff: polypropylen mit gel&auml;ppt bindeband<br />Bindemittel: bindeband<br />Innenmantel: Polyvinylchlorid( PVC)<br />Amour: verzinktem stahldraht gepanzertes( SWA) oder stahlband gepanzerten( sta)<br />Mantel: Polyvinylchlorid( PVC)</p>
<p><strong></strong>&nbsp;</p>
<p><strong>B, Funktionen</strong></p>
<p><strong>&nbsp;</strong>Vpe-isolierte stromkabel nicht nur hat ausgezeichnete elektrische, mechanischen eigenschaften, aber hat auch starke Widerstand gegen chemische korrosion, w&auml;rmebest&auml;ndigkeit und umweltfreundliches Stressresistenz. Seine Struktur ist einfach. Der langen Zeit Betriebstemperatur +90 u. Grad; c. Es ist conveninet zu bedienen und kann verlegt werden ohne Einschr&auml;nkung von anderen Ebene.</p>
<p>&nbsp;</p>
<p>Vpe-isolierte stahldraht gepanzerten stromkabel: vpe/pvc-stromkabel hat eine Reihe von Vorteilen &uuml;ber Papier isoliert und pvc-kabel. Vpe-kabel hat eine hohe spannungsfestigkeit, mechanische Festigkeit, hohe- Aging Widerstand, environmetal Stress Widerstand antichemical corrossion, und es ist einfach Bau, mit bequem und h&ouml;here operative der langfristigen Temperatur. Es verlegt werden ohne drop Einschr&auml;nkung.</p>
<p>Verschiedene Flamme- entflammbar und nicht- Flammschutzmittel vpe-kabel hergestellt werden mit drei Technologie( peroxid, silan und Bestrahlung Vernetzung). Die Flamme- entflammbare kabel deckt alle Arten von niedrig- smoke niedrigen- halogen niedrig- rauchentwicklung halogenfrei, und nicht- Rauch nonhalogented und drei Klassen eines, b, c.</p>
<p>&nbsp;</p>
<p><strong>&nbsp;<span style="font-size: 18.0px">2 </span><span style="font-size: 14.0pt">Anwendung:</span></strong></p>
<p><strong></strong>&nbsp;</p>
<p><strong>1)</strong>Diese Kabel sind am besten geeignet f&uuml;r erdverlegung oder f&uuml;r die Installation auf Tabletts oder Kan&auml;le,, wo es<br />Die Gefahr von mechanische Besch&auml;digung, armierte kabel sollte verwendet werden.</p>
<p><strong>2)</strong>F&uuml;r die Verlegung in Boden entlang Route mit gro&szlig;en Unterschied der Stufe k&ouml;nnen tragen externe mechanische Kr&auml;fte.</p>
<p>&nbsp;</p>
<p><strong><span style="font-size: 14.0pt">3 modell und Namen</span></strong></p>
<p><strong></strong>&nbsp;</p>
<p><strong></strong>&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td colspan="2">
<p><span style="font-family: arial , helvetica , sans-serif">china type</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: arial , helvetica , sans-serif">Beschreibung</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: arial , helvetica , sans-serif">Anwendung</span></p>
</td>
</tr>
<tr>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">cu</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">al</span></p>
</td>
</tr>
<tr>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjv</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjlv</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">Vpe-isolierung pvc netzkabel( Cu/vpe/PVC)</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: arial , helvetica , sans-serif">Verlegt werden drinnen, im Tunnel, kabel Furche oder Rohr, das Kabel konnte nicht tragen mechanische Kraft au&szlig;erhalb</span></p>
</td>
</tr>
<tr>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjy</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjly</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">Vpe-isolierung pe-mantel netzkabel( Cu/vpe/pe)</span></p>
</td>
</tr>
<tr>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjv22</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjlv22</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">Vpe-isolierung, stahlband r&uuml;stung, pvc netzkabel</span></p>
<p><span style="font-family: arial , helvetica , sans-serif">( Cu/vpe/PVC/sta/PVC)</span></p>
</td>
<td rowspan="3">
<p><span style="font-family: arial , helvetica , sans-serif">Verlegt werden unterirdischen, das Kabel ertragen konnte bestimmte mechanische Kraft, aber es konnte nicht tragen gro&szlig;e Zugkraft.</span></p>
</td>
</tr>
<tr>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjv23</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjlv23</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">Vpe-isolierung, stahlband r&uuml;stung, pe-mantel netzkabel</span></p>
<p><span style="font-family: arial , helvetica , sans-serif">( Cu/vpe/PVC/sta/pe)</span></p>
</td>
</tr>
<tr>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjv62</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjlv62</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">Vpe-isolierung, keine magnetismus stahlband r&uuml;stung, pe-mantel netzkabel</span></p>
</td>
</tr>
<tr>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjv32</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjlv32</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">Vpe-isolierung, d&uuml;nne Stahl- r&uuml;stung draht, pvc netzkabel</span></p>
<p><span style="font-family: arial , helvetica , sans-serif">( Cu/vpe/PVC/SWA/PVC)</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: arial , helvetica , sans-serif">F&uuml;r die gut, Wasser in und R&uuml;ckgang der Bad boden, das Kabel dosen tragen die gleichen Kraft au&szlig;erhalb der maschine mit ziehen die Kraft</span></p>
<p><span style="font-family: arial , helvetica , sans-serif">.</span></p>
</td>
</tr>
<tr>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjv72</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjlv72</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">Vpe-isolierung, haben keine der Magnetismus dickem stahl- r&uuml;stung draht, pvc netzkabel</span></p>
</td>
</tr>
<tr>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjv42</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">yjlv42</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">Vpe-isolierung, dickem stahl- r&uuml;stung draht, pvc netzkabel</span></p>
</td>
<td>
<p><span style="font-family: arial , helvetica , sans-serif">F&uuml;r die gut, unter wasser mit Ende Meer, das Kabel dosen tragen die gr&ouml;&szlig;er Druck mit f&uuml;hren, um die Pull Kraft.</span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="color: #000000;font-size: 18.0px">4 spezifikation</span></strong></p>
<p>&nbsp;</p>
<p><span style="color: #000000;font-size: 14.0px">1. uo/u: 0.6/1kv</span></p>
<p><span style="color: #000000;font-size: 14.0px">&nbsp;</span></p>
<p><span style="color: #000000;font-size: 14.0px">2. Standard angewendet: iec60502, bs6346, Gb/t12706</span></p>
<p><span style="color: #000000;font-size: 14.0px">&nbsp;</span></p>
<p><span style="color: #000000;font-size: 14.0px">3. max. Betriebstemperatur: pvc-isolierte: 70 u. Grad; c, k&ouml;nnen 90 u. Grad; c und 110 u. Grad; c je nach Anforderung</span></p>
<p><span style="color: #000000;font-size: 14.0px">Pvc-isolierte: 90 u. Grad; c, k&ouml;nnen 110 u. Grad; c je nach Anforderung</span></p>
<p><span style="color: #000000;font-size: 14.0px">&nbsp;</span></p>
<p><span style="color: #000000;font-size: 14.0px">4. Leiter: Klasse 1/2 gegl&uuml;ht blankem kupfer solide oder str&auml;nge</span></p>
<p><span style="color: #000000;font-size: 14.0px">&nbsp;</span></p>
<p><span style="color: #000000;font-size: 14.0px">5. isolierung: PVC/vpe</span></p>
<p><span style="color: #000000;font-size: 14.0px">&nbsp;</span></p>
<p><span style="color: #000000;font-size: 14.0px">6. kerne: 1c, 2c, 3c, 4c, 5c, 3c+1e, 4c+1e, 3c+2e</span></p>
<p><span style="color: #000000;font-size: 14.0px">&nbsp;</span></p>
<p><span style="color: #000000;font-size: 14.0px">7. Querschnitt: 1,5 mm2~ 630 mm2</span></p>
<p><span style="color: #000000;font-size: 14.0px">&nbsp;</span></p>
<p><span style="color: #000000;font-size: 14.0px">8. armoure: keine armoure, sta( Bemerkung: f&uuml;r einzelne die armore sollte ATA)</span></p>
<p><span style="color: #000000;font-size: 14.0px">Swa( Bemerkung: f&uuml;r einzelne die armore sollte awa)</span></p>
<p><span style="color: #000000;font-size: 14.0px">&nbsp;</span></p>
<p><span style="color: #000000;font-size: 14.0px">9. mantel: pvc</span></p>
<p><span style="color: #000000;font-size: 14.0px">&nbsp;</span></p>
<p><span style="color: #000000;font-size: 14.0px">10. Farbe: schwarz oder andere als Anfrage</span></p>
<p><span style="color: #000000;font-size: 14.0px">&nbsp;</span></p>
<p><span style="color: #000000;font-size: 14.0px">1 1. flammschutzmittel oder Feuer Widerstand oder niedrigen rauchen und halogenfrei sind.</span></p>
<p><span style="color: #000000;font-size: 14.0px">&nbsp;</span></p>
<p><span style="color: #000000;font-size: 14.0px">1 2. holz Trommel oder wie pro Antrag</span></p>
<p><span style="color: #000000;font-size: 14.0px">&nbsp;</span></p>
<p><span style="color: #000000;font-size: 14.0px"></span></p>
<p><span style="color: #000000;font-size: 14.0px"></span></p>
<p>&nbsp;</p>
<p><span style="color: #000000;font-size: 14.0px">&nbsp;</span></p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/high-quality-aycwy-cable-xlpe-insulated-power-cable-0-6-1kv/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
