<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>BS 7870-5 (AL\/XLPE) &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/bs-7870-5-al-xlpe/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Fri, 06 Sep 2019 07:55:13 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.30</generator>
	<item>
		<title>600/1000V ABC -Aerial Bundled Cables to BS 7870-5 (AL/XLPE)</title>
		<link>https://german.baoliyy.com/600-1000v-abc-aerial-bundled-cables-to-bs-7870-5-al-xlpe/</link>
				<comments>https://german.baoliyy.com/600-1000v-abc-aerial-bundled-cables-to-bs-7870-5-al-xlpe/#respond</comments>
				<pubDate>Fri, 06 Sep 2019 07:55:13 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[zzhd]]></category>
		<category><![CDATA[600\/1000V ABC]]></category>
		<category><![CDATA[BS 7870-5]]></category>
		<category><![CDATA[BS 7870-5 (AL\/XLPE)]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/600-1000v-abc-aerial-bundled-cables-to-bs-7870-5-al-xlpe/</guid>
				<description><![CDATA[600/1000 V ABC-Freileitungen nach BS 7870-5 (AL/XLPE) Produktbeschreibung 600/1000 V ABC-Freileitungen nach BS 7870-5 (AL/XLPE) BS 7870-5 (AL/XLPE) die freileitungen f&#252;r overhead verteilung linien haben alle leiter aus aluminium 1350 und mit XLPE. Phase und neutral kerne sind eine in einem b&#252;ndel mit einem links hand legen. kann verwendet werden f&#252;r festinstallation als overhead stromleitungen [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<h2>600/1000 V ABC-Freileitungen nach BS 7870-5 (AL/XLPE)</h2>
<div id="ali-anchor-AliPostDhMb-gg6jf" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-gg6jf" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Produktbeschreibung</span></div>
<div style="padding: 10.0px 0">
<h1>600/1000 V ABC-Freileitungen nach BS 7870-5 (AL/XLPE)</h1>
<h3>BS 7870-5 (AL/XLPE)</h3>
<p>die freileitungen f&uuml;r overhead verteilung linien haben alle leiter aus aluminium 1350 und mit XLPE. Phase und neutral kerne sind eine in einem b&uuml;ndel mit einem links hand legen. kann verwendet werden f&uuml;r festinstallation als overhead stromleitungen bis zu 1000 V inkl.</p>
<h3>BS 7870-5 (AL/XLPE) Standard</h3>
<p>BS 7870-5: 1999</p>
<h3>BS 7870-5 (AL/XLPE) Bau</h3>
<div style="overflow:auto"><table style="padding: 0.0px;margin: 0.0px;border: 0.0px;width: 745.0px;border-collapse: collapse;color: #333333;font-family: verdana , geneva , sans-serif;font-size: 12.0px;font-weight: normal;background-color: #ffffff">
<tbody>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<th>leiter (f&uuml;r entweder phase, neutral oder stra&szlig;enbeleuchtung)</th>
<td width="70%">die leiter werden von aluminium 1350 dr&auml;hte und sind verdichtet rund gestrandet (RM).</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<th>isolierung</th>
<td>XLPE. 1, 2 und 3 raised l&auml;ngs rippen auf der oberfl&auml;che der kerne. die oberfl&auml;che der neutralen kern sollte mindestens 12 rippen f&uuml;r abschnitte bis zu 50mm ^ 2 und ein minimum von 16 rippen f&uuml;r kerne &uuml;ber 50mm ^ 2. im fall von f&uuml;nf kern bundles die oberfl&auml;che der schutz kissenkern sollte glatt sein.</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<th>montage</th>
<td>2 bis zu 4 kerne von gleich querschnitt werden gestrandet zusammen im linken hand laien, zus&auml;tzlich 1 oder 2 kerne von reduziert querschnitt kann co-gestrandet.</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p><span style="background-color: #ffff00">ZOLL CODE/HS CODE:</span><span style="font-size: 14.0px">85444921,00</span></p>
<p>&nbsp;</p>
</p>
<p>&nbsp;</p>
<h3>BS 7870-5 (AL/XLPE) Technische Daten</h3>
<div style="overflow:auto"><table style="padding: 0.0px;margin: 0.0px;border: 0.0px;width: 646.0px;border-collapse: collapse;color: #333333;font-family: verdana , geneva , sans-serif;background-color: #ffffff;height: 100.0px">
<tbody>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td style="width: 212.0px">nennspannung</td>
<td style="width: 211.0px">kV</td>
<td style="width: 217.0px">0,6/1</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td style="width: 212.0px">testspannung</td>
<td style="width: 211.0px">Veff kV</td>
<td style="width: 217.0px">4</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td style="width: 212.0px">verlegung temperatur</td>
<td style="width: 211.0px">&deg; C</td>
<td style="width: 217.0px">min.-20</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td style="width: 212.0px">betriebstemperatur</td>
<td style="width: 211.0px">&deg; C</td>
<td style="width: 217.0px">-30 ~ + 80</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td style="width: 212.0px">leitertemperatur</td>
<td style="width: 211.0px">&deg; C</td>
<td style="width: 217.0px">max. + 80</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td style="width: 212.0px">kurzschlusstemperatur</td>
<td style="width: 211.0px">&deg; C/s</td>
<td style="width: 217.0px">max. + 130/5</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td style="width: 212.0px">biegeradius (min.)</td>
<td style="width: 211.0px">&nbsp;</td>
<td style="width: 217.0px">18 &times; o von kabel</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<h3>BS 7870-5 (AL/XLPE) Abmessungen</h3>
<div style="overflow:auto"><table style="padding: 0.0px;margin: 0.0px;border: 0.0px;text-align: center;width: 745.0px;border-collapse: collapse;color: #333333;font-family: verdana , geneva , sans-serif;background-color: #ffffff">
<tbody>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<th>anzahl der x nennquerschnitt abschnitt</th>
<th>max. leiter-widerstand</th>
<th>min. bruchlast von leiter strang</th>
<th>nennstrom in der luft</th>
<th>au&szlig;endurchmesser</th>
<th>gesamtgewicht</th>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<th>mm ^ 2</th>
<th>Ohm/km</th>
<th>kN</th>
<th>eine</th>
<th>mm</th>
<th>kg/km</th>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>1&#215;16 RM</td>
<td>1,910</td>
<td>2,5</td>
<td>72</td>
<td>80</td>
<td>74</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td>1&#215;25 RM</td>
<td>1,200</td>
<td>4,0</td>
<td>107</td>
<td>90</td>
<td>106</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>1&#215;35 RM</td>
<td>0,868</td>
<td>5,5</td>
<td>132</td>
<td>105</td>
<td>138</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td>1&#215;50 RM</td>
<td>0,641</td>
<td>8,0</td>
<td>165</td>
<td>118</td>
<td>182</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>1&#215;70 RM</td>
<td>0,443</td>
<td>10,7</td>
<td>205</td>
<td>130</td>
<td>252</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td>1&#215;95 RM</td>
<td>0,320</td>
<td>13,7</td>
<td>240</td>
<td>154</td>
<td>333</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>1&#215;120 RM</td>
<td>0,253</td>
<td>18,6</td>
<td>290</td>
<td>170</td>
<td>408</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td>1&#215;150 RM</td>
<td>0,206</td>
<td>23,2</td>
<td>334</td>
<td>190</td>
<td>502</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>1&#215;185 RM</td>
<td>0,164</td>
<td>28,7</td>
<td>389</td>
<td>210</td>
<td>611</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td>1&#215;240 RM</td>
<td>0,125</td>
<td>37,2</td>
<td>467</td>
<td>240</td>
<td>801</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>2&#215;16 RM</td>
<td>1,910</td>
<td>2,5</td>
<td>72</td>
<td>156</td>
<td>147</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td>2&#215;25 RM</td>
<td>1,200</td>
<td>4,0</td>
<td>107</td>
<td>180</td>
<td>208</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>2&#215;35 RM</td>
<td>0,868</td>
<td>5,5</td>
<td>132</td>
<td>200</td>
<td>277</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td>2&#215;50 RM</td>
<td>0,641</td>
<td>8,0</td>
<td>165</td>
<td>235</td>
<td>361</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>2&#215;70 RM</td>
<td>0,443</td>
<td>10,7</td>
<td>205</td>
<td>254</td>
<td>505</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td>2&#215;95 RM</td>
<td>0,320</td>
<td>13,7</td>
<td>240</td>
<td>303</td>
<td>666</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>2&#215;150 RM</td>
<td>0,206</td>
<td>23,2</td>
<td>334</td>
<td>380</td>
<td>1004</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td>4&#215;16 RM</td>
<td>1,910</td>
<td>2,5</td>
<td>72</td>
<td>188</td>
<td>286</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>4&#215;25 RM</td>
<td>1,200</td>
<td>4,0</td>
<td>107</td>
<td>212</td>
<td>430</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td>4&#215;35 RM</td>
<td>0,868</td>
<td>5,5</td>
<td>132</td>
<td>241</td>
<td>553</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>4&#215;50 RM</td>
<td>0,641</td>
<td>8,0</td>
<td>165</td>
<td>278</td>
<td>746</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td>4&#215;70 RM</td>
<td>0,443</td>
<td>10,7</td>
<td>205</td>
<td>318</td>
<td>1009</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>4&#215;95 RM</td>
<td>0,320</td>
<td>13,7</td>
<td>240</td>
<td>378</td>
<td>1332</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td>4&#215;120 RM</td>
<td>0,253</td>
<td>18,6</td>
<td>290</td>
<td>544</td>
<td>1632</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>4&#215;50 + 1&#215;25 RM</td>
<td>0,641/1,200</td>
<td>8,0/4,0</td>
<td>165/107</td>
<td>319</td>
<td>814</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td>4&#215;50 + 1&#215;35 RM</td>
<td>0,641/0,868</td>
<td>8,5/5,5</td>
<td>165/132</td>
<td>319</td>
<td>845</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>4&#215;70 + 1&#215;25 RM</td>
<td>0,443/1,200</td>
<td>10,7/4,0</td>
<td>205/107</td>
<td>360</td>
<td>1105</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td>4&#215;70 + 2&#215;25 RM</td>
<td>0,443/1,200</td>
<td>10,7/4,0</td>
<td>205/107</td>
<td>400</td>
<td>1217</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>4&#215;95 + 1&#215;25 RM</td>
<td>0,320/1,200</td>
<td>13,7/4,0</td>
<td>240/107</td>
<td>418</td>
<td>1438</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px;background-color: #ebebeb">
<td>4&#215;95 + 2&#215;25 RM</td>
<td>0,320/1,200</td>
<td>13,7/4,0</td>
<td>240/107</td>
<td>420</td>
<td>1544</td>
</tr>
<tr style="padding: 0.0px;margin: 0.0px;border: 0.0px">
<td>4&#215;120 + 1&#215;25 RM</td>
<td>0,253/1,200</td>
<td>18,6/4,0</td>
<td>290/107</td>
<td>590</td>
<td>2050</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p>andere querschnitten auf anfrage</p>
<h4><span style="background-color: #ffff00">zertifikate, zulassungen:</span></h4>
<p><span style="font-size: 14.0px">CCC, ISO</span></p>
<p><span style="font-size: 14.0px">&nbsp;</span></p>
<p><span style="font-size: 14.0px">die kabel nicht enthalten substanzen auf die reichweite liste.</span></p>
<p>&nbsp;</p>
<p><span style="font-size: 14.0px">alle substanzen der kabel erf&uuml;llen die anforderungen der rohs-richtlinie.</span></p>
<p><span style="font-size: 14.0px"></span></p>
<p>&nbsp;</p>
<h3><span style="background-color: #ffff00">600/1000 V ABC-Freileitungen nach BS 7870-5 (AL/XLPE) Bild:</span></h3>
</div>
</div>
<div>
</p>
</p>
</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div>
<div id="ali-anchor-AliPostDhMb-gvshb" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-gvshb" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">verpackung &amp; Versand</span></div>
<div style="padding: 10.0px 0">
<p><span style="background-color: #ff99cc"><strong><span style="color: #000000;font-size: 16.0px;font-family: calibri , zapf dingbats">verpackung:</span></strong></span></p>
<p>stahl holz trommel (begasung)<br />kabel l&auml;nge in jede trommel: 500 mt/1000 mt oder wie pro tats&auml;chlichen kabell&auml;nge anforderungen.</p>
<p><strong><span style="color: #000000;font-size: 16.0px;font-family: calibri , zapf dingbats;background-color: #ff99cc">Drum gr&ouml;&szlig;e:</span></strong><br />wie pro kabel l&auml;nge und container gr&ouml;&szlig;e<br />* um ihnen genaue preis freundlich erkl&auml;ren sie uns ihre ben&ouml;tigt kabel l&auml;nge menge. gr&ouml;&szlig;ere menge, mehr rabatt nutzen bereit f&uuml;r sie!</p>
<p><span style="font-size: 16.0px;background-color: #ff99cc"><strong><span style="color: #000000;font-family: calibri , zapf dingbats">versand:</span></strong></span><br />Port: Tianjin, Qingdao, oder andere ports wie pro ihre requireents.</p>
<p><span style="background-color: #ff99cc"><strong><span style="color: #000000;font-size: 16.0px;font-family: calibri , zapf dingbats">seefracht:</span></strong></span><br />FOB/C &amp; F/CIF angebot sind alle vorhanden.</p>
<p>&nbsp;</p>
</p>
</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-mvf5l" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-mvf5l" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Unternehmensinformationen</span></div>
<div style="padding: 10.0px 0">
<p align="center" style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;font-size: 12.0px;font-style: normal;font-weight: normal;line-height: 18.0px;vertical-align: baseline;color: #333333;text-align: left;background-color: #ffffff"><strong><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: calibri , zapf dingbats;font-size: 18.0px;font-style: inherit;line-height: 18.0px;vertical-align: baseline;color: #ffffff;background-color: #3366ff"><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-style: normal;line-height: normal;vertical-align: baseline">Unternehmensprofil</span></span></strong></p>
<p>Hongda cable Co., ltd ist einer der professionellsten kabel &amp; draht hersteller unter moderne enterprise-system in China, wurde gegr&uuml;ndet 1999, integration der wissenschaftlichen forschung, entwicklung, produktion und vertrieb. das unternehmen produziert haupts&auml;chlich 1-35 kV stromkabel, 35mm kabel in elektrische dr&auml;hte, AAC, AAAC, ACSR.</p>
<p>unsere vorteile</p>
<p>1. Mit mehr als 17 jahre erfahrung, unsere produkte sind streng in &uuml;bereinstimmung mit ISO, CE, UL und BV;</p>
<p>2. Gute kosten steuerung, mit hoch wettbewerbsf&auml;higen preisen;</p>
<p>3. Starke und Professionelle R &amp; D team ihre spezifischen bed&uuml;rfnisse zu erf&uuml;llen;</p>
<p>4. Schnelle lieferung &amp; zuverl&auml;ssige produkte sind immer der grund, warum sie uns.</p>
</p>
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-0os3u" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-0os3u" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Kontaktinformationen</span></div>
<div style="padding: 10.0px 0">
<p><strong><span style="color: #0000ff;font-size: 16.0px">kontaktinformationen</span></strong></p>
<p><span style="color: #0000ff;font-size: 16.0px">&nbsp;</span></p>
<p><span style="color: #0000ff;font-size: 16.0px">alle bed&uuml;rfnisse oder frage, kontaktieren sie uns bitte, wir werden mehr vergn&uuml;gen, service sie.</span></p>
<p><span style="color: #0000ff;font-size: 16.0px">&nbsp;</span></p>
<p><span style="color: #0000ff;font-size: 16.0px">wir freuen uns auf ihre anfrage und nizza cooperaton.</span></p>
<p>&nbsp;</p>
</p>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/600-1000v-abc-aerial-bundled-cables-to-bs-7870-5-al-xlpe/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>