<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Copper conductor three phase cable &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/copper-conductor-three-phase-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Tue, 21 Jun 2022 00:17:27 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.28</generator>
	<item>
		<title>11kV 3*185mm Copper conductor three phase cable</title>
		<link>https://german.baoliyy.com/11kv-3185mm-copper-conductor-three-phase-cable/</link>
				<comments>https://german.baoliyy.com/11kv-3185mm-copper-conductor-three-phase-cable/#respond</comments>
				<pubDate>Tue, 21 Jun 2022 00:17:27 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[sonorouscable]]></category>
		<category><![CDATA[11kV 3*185mm three phase cable]]></category>
		<category><![CDATA[Copper conductor three phase cable]]></category>
		<category><![CDATA[three phase cable]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/11kv-3185mm-copper-conductor-three-phase-cable/</guid>
				<description><![CDATA[11kV 3*185mm kupferleiter drei phase kabel &#160; 1. Vpe-isolierte 3*185mm2. Nennspannung: 8,7/15 kv3. Kerne: 34. Abschnitt bereich: 1,5 ~ 630mm2 &#160; &#160; typ von vpe-isolierte stromkabel: Cu oder Al/XLPE/CTS oder CWS/PVC stromkabel Cu oder Al/XLPE/CTS oder CWS/PVC/SWA/PVC stromkabel &#160; &#160; &#160; &#160; &#160; &#160; &#160; &#160; anwendung: das produkt ist geeignet f&#252;r den einsatz in [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><strong><span style="font-size: 14.0px">11kV 3*185mm kupferleiter drei phase kabel</span></strong></p>
<p>&nbsp;</p>
<p><span style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 15.0px;font-size: 14.0px">1. Vpe-isolierte 3*185mm</span><br /><span style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 15.0px;font-size: 14.0px">2. Nennspannung: 8,7/15 kv</span><br /><span style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 15.0px;font-size: 14.0px">3. Kerne: 3</span><br /><span style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 15.0px;font-size: 14.0px">4. Abschnitt bereich: 1,5 ~ 630mm2</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="color: #333333;font-family: arial , helvetica , sans-serif;font-size: 14.0px"><span style="line-height: 15.0px">typ von vpe-isolierte stromkabel:</span></span></strong></p>
<p align="left"><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , sans-serif">Cu oder Al/XLPE/CTS oder CWS/PVC stromkabel</span></p>
<p align="left"><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , sans-serif">Cu oder Al/XLPE/CTS oder CWS/PVC/SWA/PVC stromkabel</span></p>
<p align="left">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="color: #333333;font-family: arial , helvetica , sans-serif;font-size: 14.0px"><span style="line-height: 15.0px"><span style="font-style: normal;line-height: normal">anwendung:</span></span></span></strong></p>
<p><strong></strong><span style="font-size: 14.0px"><span style="line-height: normal;font-family: arial , sans-serif">das produkt ist geeignet f&uuml;r den einsatz in energie&uuml;bertragung und-verteilung leitungen mit nennwechselspannung 3,6/6kV</span><span style="font-family: verdana , arial , helvetica , sans-serif;line-height: normal">~</span><span style="line-height: normal;font-family: arial , sans-serif">26/35kV.</span><span style="line-height: normal;font-family: arial , sans-serif">f&uuml;r die verlegung im innenbereich, in tunnel, kabel graben, gut oder direkt im boden.</span><span style="line-height: 18.0px;font-family: verdana , arial , helvetica , sans-serif">&nbsp;</span></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="color: #333333;font-family: arial , helvetica , sans-serif;font-size: 14.0px"><span style="line-height: 15.0px"><span style="font-style: normal;line-height: normal"><span style="font-style: normal;line-height: normal;font-family: arial , sans-serif">Feature:</span></span></span></span></strong></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">1. Die h&ouml;chsten erlaubt betriebstemperatur des leiters f&uuml;r langfristige arbeits ist 90 grad.</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">2. In kurzschluss (Max langfristige ist nicht mehr als 5 sekunden). die h&ouml;chste temperatur f&uuml;r leiter ist nicht mehr als 250 grad.</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">3. Das kabel ist gelegt ohne horizontale drop grenze. die umgebungstemperatur sollte nicht niedriger als 0 wenn legen. andernfalls es sollte vorgew&auml;rmt.</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">4. Ausgezeichnete elektrische leistung, best&auml;ndigkeit gegen chemische korrosion.</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">5. Can stehen ratsam traktion gelegt. stehen traktion von au&szlig;en. links low smoke halogenfrei nach verbrannt. verz&ouml;gern die verbrennung der kabel.</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px"><strong><span style="color: #333333">nenn querschnitts Bereichen:</span></strong></span></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">1,5 mm2, 2,5 mm2, 4 mm2, 6 mm2, 10 mm2, 16 mm2, 25 mm2, 35 mm2, 50 mm2, 70 mm2, 95 mm2, 120 mm2, 150 mm2, 185 mm2, 240 mm2, 300 mm2, 400 mm2, 500 mm2, 630 mm2, 800 mm2</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px"><strong><span style="color: #333333">produktionsbereich:</span></strong></span></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">einzelader netzkabel: von 1,5 mm2 zu 800 mm2,</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px">Multi-kernnetzkabel: von 1,5 mm2 zu 400 mm2</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span style="font-family: arial , helvetica , sans-serif;color: #333333;font-size: 14.0px"><span style="font-style: normal;line-height: normal">spezifikation:</span></span></strong></p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="left">
<td colspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">leiter</span></p>
</td>
<td rowspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">struktur</span></p>
</td>
<td rowspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">anwendung</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Cu</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">Al</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJV</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJLV</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">vpe-isolierung PVC-mantel netzkabel (Cu/XLPE/PVC)</span></p>
</td>
<td rowspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">zu verlegt werden drinnen, in tunnel, kabel furche oder rohr, das kabel konnte nicht tragen mechanische kraft au&szlig;erhalb</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJY</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJLY</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">vpe-isolierung PE mantel netzkabel (Cu/XLPE/PE)</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJV22</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJLV22</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">vpe-isolierung, stahlband r&uuml;stung, PVC-mantel netzkabel</span></p>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">( Cu/XLPE/PVC/STA/PVC)</span></p>
</td>
<td rowspan="3">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">um unterirdisch verlegt werden, das kabel k&ouml;nnten bestimmte mechanische kraft zu tragen, aber es konnte nicht gro&szlig;e zugkraft zu tragen.</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJV23</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJLV23</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">vpe-isolierung, stahlband r&uuml;stung, PE mantel netzkabel</span></p>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">( Cu/XLPE/PVC/STA/PE)</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJV62</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJLV62</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">vpe-isolierung, keine magnetismus stahlband r&uuml;stung, PE mantel netzkabel</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJV32</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJLV32</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">vpe-isolierung, d&uuml;nnen stahldraht r&uuml;stung, PVC-mantel netzkabel</span></p>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">( Cu/XLPE/PVC/SWA/PVC)</span></p>
</td>
<td rowspan="2">
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">f&uuml;r die gut, wasser innen und fallen in den schlechten boden, die kabeldosen tragen die gleiche kraft au&szlig;erhalb der maschine mit ziehen sie die kraft</span></p>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">.</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJV72</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJLV72</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">vpe-isolierung, haben keine der magnetismus dicken stahldraht r&uuml;stung, PVC-mantel netzkabel</span></p>
</td>
</tr>
<tr align="left">
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJV42</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">YJLV42</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">vpe-isolierung, dicken stahldraht r&uuml;stung, PVC-mantel netzkabel</span></p>
</td>
<td>
<p><span style="font-style: normal;font-weight: normal;font-size: 14.0px;line-height: normal;font-family: arial , helvetica , sans-serif">f&uuml;r die gut, unterwasser mit der unterseite meer, die kabeldosen tragen die gr&ouml;&szlig;ere druck mit blei zu ziehen sie die kraft.</span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="font-size: 14.0px;color: #000000"><strong>einige bilder unserer waren:</strong></span></p>
</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p style="border: 0.0px currentcolor;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><strong><span style="font-size: 14.0px">kontakt:</span></strong></p>
<p style="border: 0.0px currentcolor;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><strong></strong><strong><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica , sans-serif;font-size: 14.0px;font-style: inherit;line-height: 24.0px;vertical-align: baseline;color: #008000">frau echo</span></strong></p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><strong><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica , sans-serif;font-size: 14.0px;font-style: inherit;line-height: 24.0px;vertical-align: baseline;color: #008000">handy/wechat/whatsapp: 0086 15106980528</span></strong></p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><strong><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica , sans-serif;font-size: 14.0px;font-style: inherit;line-height: 24.0px;vertical-align: baseline;color: #008000">Skype: hongliangcablesales7</span></strong></p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><strong><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica , sans-serif;font-size: 14.0px;font-style: inherit;line-height: 24.0px;vertical-align: baseline;color: #008000">E-m: hongliangcable7 (at) hldlcable.com</span></strong></p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/11kv-3185mm-copper-conductor-three-phase-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
