<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Copper Conductor XLPE Insulation PVC Sheath &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/copper-conductor-xlpe-insulation-pvc-sheath/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Thu, 19 Mar 2020 19:22:56 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.26</generator>
	<item>
		<title>Electrical Power Cable Cu/XLPE/PVC 1*300 mm2 0.6/1KV N2XY Cable</title>
		<link>https://german.baoliyy.com/electrical-power-cable-cu-xlpe-pvc-1300-mm2-0-6-1kv-n2xy-cable/</link>
				<comments>https://german.baoliyy.com/electrical-power-cable-cu-xlpe-pvc-1300-mm2-0-6-1kv-n2xy-cable/#respond</comments>
				<pubDate>Thu, 19 Mar 2020 19:22:56 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[shancable]]></category>
		<category><![CDATA[Copper Conductor XLPE Insulation PVC Sheath]]></category>
		<category><![CDATA[CU\/XLPE\/PVC]]></category>
		<category><![CDATA[electrical power cable]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/electrical-power-cable-cu-xlpe-pvc-1300-mm2-0-6-1kv-n2xy-cable/</guid>
				<description><![CDATA[Elektrische Power Kabel Cu/XLPE/PVC 1*300 mm2 0,6/1KV N2XY Kabel &#160; Bau Leiter: Kupfer leiter, Cl.2 als pro IEC 60228 Isolierung: XLPE (vernetzte polyethylen) bewertet zu 90℃ Mantel:PVC typ ST2Zu IEC 60502, schwarz &#160; Code BezeichnungYJ: vpe-isolierungV: PVC mantelZR: Schwer Entflammbar AnwendungenF&#252;r verlegung drinnen und drau&#223;en. In der lage zu tragen bestimmte traktion w&#228;hrend der installation, [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="line-height: 19.0px;font-family: arial;font-size: 10.0pt;font-style: inherit;font-weight: bold">Elektrische Power Kabel Cu/XLPE/PVC 1*300 mm2 0,6/1KV N2XY Kabel</span></p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333">&nbsp;</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="line-height: 19.0px;font-family: arial;font-size: 10.0pt;font-style: inherit;font-weight: bold">Bau</span></p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial;font-size: 10.0pt;line-height: normal;vertical-align: baseline;color: #231f20">Leiter: Kupfer leiter, Cl.2 als pro IEC 60228</span></p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial;font-size: 10.0pt;line-height: normal;vertical-align: baseline;color: #231f20">Isolierung: XLPE (vernetzte polyethylen) bewertet zu 90</span><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 10.0pt;line-height: normal;vertical-align: baseline">℃</span></p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial;font-size: 10.0pt;line-height: normal;vertical-align: baseline;color: #231f20">Mantel:</span><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 10.0pt;line-height: normal;vertical-align: baseline;color: #231f20">PVC typ ST</span><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 10.0pt;line-height: normal;vertical-align: baseline;color: #231f20">2</span><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 10.0pt;line-height: normal;vertical-align: baseline;color: #231f20">Zu IEC 60502, schwarz</span></p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333">&nbsp;</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="font-weight: bold">Code Bezeichnung</span><br />YJ: vpe-isolierung<br />V: PVC mantel<br />ZR: Schwer Entflammbar</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="font-weight: bold">Anwendungen</span><br />F&uuml;r verlegung drinnen und drau&szlig;en. In der lage zu tragen bestimmte traktion w&auml;hrend der installation, aber nicht externe mechanische kr&auml;fte. Verlegung single-core kabel in magnetische kan&auml;le ist nicht erlaubt.</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="font-weight: bold">Standards</span><br />International: IEC 60502, IEC 60228, (IEC 60332-3 f&uuml;r ZR-YJV nur)<br />China: GB/T 12706, (GB/T 18380-3 f&uuml;r ZR-YJV nur)<br />Andere standards wie BS, DIN und ICEA auf anfrage</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="font-weight: bold">Technische daten</span><br />Nennspannung: 0,6/1 kV<br />Maximale Leiter Temperatur: unter normalen (90℃), notfall (130℃) oder kurzschluss keine mehr als 5 s (250℃) bedingungen.<br />Min. Umgebungs Temp. -15℃, Installation ℃<br />Min. Biegen Radius: 20 x kabel OD f&uuml;r single-core<br />15 x kabel OD f&uuml;r multi core</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="font-weight: bold">Zertifikate</span><br />CE, RoHS, CCC, KEMA und mehr andere auf anfrage</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333">
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333">&nbsp;</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333">
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333">&nbsp;</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333">
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/electrical-power-cable-cu-xlpe-pvc-1300-mm2-0-6-1kv-n2xy-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>Electrical Power Cable Cu/XLPE/PVC 1*630 mm2 0.6/1KV 2015 Hot Sale</title>
		<link>https://german.baoliyy.com/electrical-power-cable-cu-xlpe-pvc-1630-mm2-0-6-1kv-2015-hot-sale/</link>
				<comments>https://german.baoliyy.com/electrical-power-cable-cu-xlpe-pvc-1630-mm2-0-6-1kv-2015-hot-sale/#respond</comments>
				<pubDate>Thu, 19 Mar 2020 19:21:01 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[shancable]]></category>
		<category><![CDATA[Copper Conductor XLPE Insulation PVC Sheath]]></category>
		<category><![CDATA[CU\/XLPE\/PVC]]></category>
		<category><![CDATA[electrical power cable]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/electrical-power-cable-cu-xlpe-pvc-1630-mm2-0-6-1kv-2015-hot-sale/</guid>
				<description><![CDATA[Bau Leiter: kupferleiter, cl. 2 nach iec 60228 Isolierung: vpe( Kreuz- verbunden Polyethylen) bewertet 90&#38; #8451; Mantel:Pvc-typ st2Iec 60502, schwarz &#160; Code BezeichnungYj: vpe-isolierungV: pvc-mantelZr: schwer entflammbar AnwendungenF&#252;r die Verlegung drinnen und drau&#223;en. K&#246;nnen tragen bestimmte Traktion w&#228;hrend der Installation, aber nicht externe mechanische Kr&#228;fte. Verlegung aderleitung in magnetischen Kan&#228;le ist nicht erlaubt. StandardsInternationalen: iec [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="line-height: 19.0px;font-family: arial;font-size: 10.0pt;font-style: inherit;font-weight: bold">Bau</span></p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial;font-size: 10.0pt;line-height: normal;vertical-align: baseline;color: #231f20">Leiter: kupferleiter, cl. 2 nach iec 60228</span></p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial;font-size: 10.0pt;line-height: normal;vertical-align: baseline;color: #231f20">Isolierung: vpe( Kreuz- verbunden Polyethylen) bewertet 90</span><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 10.0pt;line-height: normal;vertical-align: baseline">&amp; #8451;</span></p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial;font-size: 10.0pt;line-height: normal;vertical-align: baseline;color: #231f20">Mantel:</span><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 10.0pt;line-height: normal;vertical-align: baseline;color: #231f20">Pvc-typ st</span><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 10.0pt;line-height: normal;vertical-align: baseline;color: #231f20">2</span><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 10.0pt;line-height: normal;vertical-align: baseline;color: #231f20">Iec 60502, schwarz</span></p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333">&nbsp;</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="font-weight: bold">Code Bezeichnung</span><br />Yj: vpe-isolierung<br />V: pvc-mantel<br />Zr: schwer entflammbar</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="font-weight: bold">Anwendungen</span><br />F&uuml;r die Verlegung drinnen und drau&szlig;en. K&ouml;nnen tragen bestimmte Traktion w&auml;hrend der Installation, aber nicht externe mechanische Kr&auml;fte. Verlegung aderleitung in magnetischen Kan&auml;le ist nicht erlaubt.</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="font-weight: bold">Standards</span><br />Internationalen: iec 60502, iec 60228,( IEC 60332-3 f&uuml;r zr-yjv nur)<br />China: gb/t 12706,( GB/t 18380-3 f&uuml;r zr-yjv nur)<br />Andere Standards wie bs, din und ICEA auf Anfrage</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="font-weight: bold">technische Daten</span><br />Nennspannung: 0,6/1 kv<br />Maximale Leiter Temperatur: unter normalen( 90&amp; #8451;), Notfall( 130&amp; #8451;) oder Kurzschluss nicht mehr als 5 s( 250&amp; #8451;) Bedingungen.<br />Min. Umgebungstemperatur.- 15&amp; #8451;, Installation und #8451;<br />Min. Biegeradius: 20 x kabel o. D f&uuml;r single-core<br />15 x kabel o. D f&uuml;r Multi-Core</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333"><span style="font-weight: bold">Zertifikate</span><br />Ce, rohs, ccc, KEMA und andere auf Anfrage</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333">
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333">&nbsp;</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333">
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333">&nbsp;</p>
<p style="border: 0.0px;font-family: arial , helvetica;line-height: 18.0px;vertical-align: baseline;color: #333333">
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/electrical-power-cable-cu-xlpe-pvc-1630-mm2-0-6-1kv-2015-hot-sale/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
