<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>EV charging cables &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/ev-charging-cables/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Mon, 20 Jun 2022 16:26:06 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.28</generator>
	<item>
		<title>factory selling IEC62196 type 2 plugs&#038;EV charging cables</title>
		<link>https://german.baoliyy.com/factory-selling-iec62196-type-2-plugsev-charging-cables/</link>
				<comments>https://german.baoliyy.com/factory-selling-iec62196-type-2-plugsev-charging-cables/#respond</comments>
				<pubDate>Mon, 20 Jun 2022 16:26:06 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[jinshui]]></category>
		<category><![CDATA[EV charging cables]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/factory-selling-iec62196-type-2-plugsev-charging-cables/</guid>
				<description><![CDATA[fabrik verkauf IEC62196 typ 2 stecker &#38; EV ladekabel Produktbeschreibung &#160; einsatzanordnungen und funktionale defination: Mark funktionale defination 1-(L1) AC power 2-(L2) AC power 3-(L3) AC power 4-(N) Netural 5-(PE) PE 6-(CP) Control best&#228;tigung 7-(PP) verbindung best&#228;tigung FEATURES: 1. Chargingg stecker erf&#252;llen 62196-2 IEC2010 BLATT 2-lle standard 2. Produkt montage erf&#252;llen GB/T 20234,2-2011 lademodus 3 [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<h2>fabrik verkauf IEC62196 typ 2 stecker &amp; EV ladekabel</h2>
<div id="ali-anchor-AliPostDhMb-7i5vw" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-7i5vw" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Produktbeschreibung</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">einsatzanordnungen und funktionale defination:</p>
<div style="overflow:auto"><table style="width: 759.0px;border: 1.0px solid #000000;border-collapse: collapse;color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">
<tbody>
<tr style="background: #ffffff">
<th style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px;background: #555555;color: #ffffff">Mark</th>
<th style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px;background: #555555;color: #ffffff">funktionale defination</th>
</tr>
<tr style="background: #eeeeee">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">1-(L1)</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">AC power</td>
</tr>
<tr style="background: #ffffff">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">2-(L2)</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">AC power</td>
</tr>
<tr style="background: #eeeeee">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">3-(L3)</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">AC power</td>
</tr>
<tr style="background: #ffffff">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">4-(N)</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">Netural</td>
</tr>
<tr style="background: #eeeeee">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">5-(PE)</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">PE</td>
</tr>
<tr style="background: #ffffff">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">6-(CP)</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">Control best&auml;tigung</td>
</tr>
<tr style="background: #eeeeee">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">7-(PP)</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">verbindung best&auml;tigung</td>
</tr>
</tbody>
</table></div>
<h2 style="margin: 17.0px 0.0px 8.5px;padding: 0.0px;color: #4f4f4f;font-size: 18.0px;font-weight: 600;font-family: arial , sans-serif;font-style: normal;background-color: #ffffff">FEATURES:</h2>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">1. Chargingg stecker erf&uuml;llen 62196-2 IEC2010 BLATT 2-lle standard</p>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">2. Produkt montage erf&uuml;llen GB/T 20234,2-2011 lademodus 3 verbindungsmethode B2</p>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">3. Nice aussehen, hand ergonomisches design, einfache plug</p>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">4. Zuverl&auml;ssigkeit von materialien, antiflaming, druck, abriebfestigkeit, schlagfestigkeit und hohe &ouml;l.</p>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">5. Ausgezeichnete schutz leistung, schutzgrad IP55 (Arbeits zustand)</p>
<div style="overflow:auto"><table style="width: 759.0px;border: 1.0px solid #000000;border-collapse: collapse;color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">
<tbody>
<tr style="background: #ffffff">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">nennstrom</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">16A/32A/63A</td>
</tr>
<tr style="background: #eeeeee">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">betriebsspannung</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">250 V AC</td>
</tr>
<tr style="background: #ffffff">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">isolierung resisitance</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">&gt; 1000 Mt (DC500V)</td>
</tr>
<tr style="background: #eeeeee">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">Therminal temperaturanstieg</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">&lt; 50 Karat</td>
</tr>
<tr style="background: #ffffff">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">spannungsfestigkeit</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">2000 V</td>
</tr>
<tr style="background: #eeeeee">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">vibrationsfestigkeit</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">erf&uuml;llen JDQ53.36.1.1-53.36.1.2 anforderungen</td>
</tr>
<tr style="background: #ffffff">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">kontaktwiderstand</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">0,5 mMax</td>
</tr>
<tr style="background: #eeeeee">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">mechanische lebensdauer</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">keine last stecker in/ziehen &gt; 10000 mal</td>
</tr>
<tr style="background: #ffffff">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">einsetzen und Rauch-extraktion Kraft</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">45N &lt; F &lt; 80N</td>
</tr>
<tr style="background: #eeeeee">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">Shell-material</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">thermoplast (Isolator entflammbarkeit UL94 V-0)</td>
</tr>
<tr style="background: #ffffff">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">Kontaktstift</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">kupferlegierung, silber oder vernickelt</td>
</tr>
<tr style="background: #eeeeee">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">dichtung</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">gummi oder silikongummi</td>
</tr>
<tr style="background: #ffffff">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">betriebstemperatur</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">-30 &deg; C ~ + 50 &deg; C</td>
</tr>
</tbody>
</table></div>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">modell auswahl und die standard verdrahtung:</p>
<div style="overflow:auto"><table style="width: 759.0px;border: 1.0px solid #000000;border-collapse: collapse;color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">
<tbody>
<tr style="background: #ffffff">
<th style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px;background: #555555;color: #ffffff">modell</th>
<th style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px;background: #555555;color: #ffffff">anzahl von eins&auml;tzen</th>
<th style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px;background: #555555;color: #ffffff">kabel Spec.</th>
<th style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px;background: #555555;color: #ffffff">bemerkung</th>
</tr>
<tr style="background: #eeeeee">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">DSIEC2b-EV16P</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">7</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">3*2.5mm2 + 2*0.5mm2</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px" rowspan="3">die l&auml;nge des kabels kann angepasst werden</td>
</tr>
<tr style="background: #ffffff">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">DSIEC2b-EV32P</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">7</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">3*6mm2 + 2*0.5mm2</td>
</tr>
<tr style="background: #eeeeee">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">DSIEC2b-EV63P</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">7</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">3*16mm2 + 2*0.5mm2</td>
</tr>
</tbody>
</table></div>
<div style="overflow:auto"><table style="width: 759.0px;border: 1.0px solid #000000;border-collapse: collapse;color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">
<tbody>
<tr style="background: #ffffff">
<th style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px;background: #555555;color: #ffffff">modell</th>
<th style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px;background: #555555;color: #ffffff">anzahl von eins&auml;tzen</th>
<th style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px;background: #555555;color: #ffffff">kabel Spec.</th>
<th style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px;background: #555555;color: #ffffff">bemerkung</th>
</tr>
<tr style="background: #eeeeee">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">V2-DSS-EV16P</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">5</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">3*2.5mm2 + 2*0.5mm2</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px" rowspan="3">die l&auml;nge des kabels kann angepasst werden</td>
</tr>
<tr style="background: #ffffff">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">V2-DSS-EV32P</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">5</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">3*6mm2 + 2*0.5mm2</td>
</tr>
<tr style="background: #eeeeee">
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">V2-DSS-EV70P</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">5</td>
<td style="border: 1.0px solid #000000;border-collapse: collapse;padding: 7.0px 10.0px">2*13.3mm2 + 1*10mm2 + 2*0.5mm2</td>
</tr>
</tbody>
</table></div>
<h2 style="margin: 17.0px 0.0px 8.5px;padding: 0.0px;color: #4f4f4f;font-size: 18.0px;font-weight: 600;font-family: arial , sans-serif;font-style: normal;background-color: #ffffff">MECHANISCHE EIGENSCHAFTEN:</h2>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">1. Mechanische lebensdauer: leerlauf stecker in/ziehen &gt; 10000 mal</p>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">2. Impat von externen kraft: k&ouml;nnen leisten 1 Mt drop und 2 t fahrzeug laufen druck.</p>
<h2 style="margin: 17.0px 0.0px 8.5px;padding: 0.0px;color: #4f4f4f;font-size: 18.0px;font-weight: 600;font-family: arial , sans-serif;font-style: normal;background-color: #ffffff">ELEKTRISCHE LEISTUNG</h2>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">1. bemessungsbetriebsstrom: 16 V oder 32A</p>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">2. betriebsspannung: 250 V</p>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">3. isolationswiderstand: &gt; 1000MO (DC500V)</p>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">4. Terminal temperaturanstieg: &lt; 50 Karat</p>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">5. spannungsfestigkeit: 2000 V</p>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">6. Kontaktwiderstand: 0.5mO Max</p>
<h2 style="margin: 17.0px 0.0px 8.5px;padding: 0.0px;color: #4f4f4f;font-size: 18.0px;font-weight: 600;font-family: arial , sans-serif;font-style: normal;background-color: #ffffff">ANGEWANDTE MATERIALIEN:</h2>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">1. Fall Material: Thermoplast, flamme restardant grade UL94V-0</p>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">2. Contact busch: kupferlegierung, silber pflanzen</p>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">Environmentol leistung:</p>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">betriebstemperatur:-30 &amp; #8451; ~ + 50 &amp; #8451;</p>
<p style="color: #333333;font-family: arial , sans-serif;font-size: 14.0px;font-style: normal;font-weight: normal;background-color: #ffffff">
</div>
</div>
<div id="ali-anchor-AliPostDhMb-c3arj" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-c3arj" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">verpackung &amp; Versand</span></div>
<div style="padding: 10.0px 0">
<p><strong>verpackung von $ K1 $</strong></p>
</p>
<p>versand von $ K1 $</p>
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-1t17w" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-1t17w" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">unsere Dienstleistungen</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-size: 14.0px">1. ihre anfrage in 24 arbeitsstunden</span><br /><span style="font-size: 14.0px">2. Erfahrene mitarbeiter beantworten alle ihre fragen auf flie&szlig;endes Englisch.</span><br /><span style="font-size: 14.0px">3. Customized design ist verf&uuml;gbar. UEM &amp; UBM sind willkommen.</span><br /><span style="font-size: 14.0px">4. Exklusive und einzigartige l&ouml;sung zur verf&uuml;gung gestellt werden unsere kunden durch unsere gut ausgebildete und professionelle ingenieure und mitarbeiter.</span><br /><span style="font-size: 14.0px">5. sonderrabatt und schutz der verk&auml;ufe sind, um unser verteiler vorgesehen.</span><br /><span style="font-size: 14.0px">6. Probe: Wir k&ouml;nnen senden probe f&uuml;r test in einer woche, wenn die auftragsquantit&auml;t gro&szlig; ist genug. aber die versandkosten ist in der regel durch ihre seite getragen, die geb&uuml;hren werden erholte wenn wir haben formale ordnung.</span><br /><span style="font-size: 14.0px">7. Als ehrlicher verk&auml;ufer, wir immer &uuml;berlegen rohstoff, erweiterte maschinen, qualifizierte techniker, um sicherzustellen, unsere produkte werden in hoher qualit&auml;t und stabile funktion. kontaktieren sie uns oder besuchen sie unsere unternehmen.</span></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-ib714" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-ib714" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Unternehmensinformationen</span></div>
<div style="padding: 10.0px 0">
<p style="text-align: center"><span style="font-size: 24.0px;color: #ff0000"><strong>UNTERNEHMENSINFORMATIONEN UND PRODUKTIONSFORTSCHRITT</strong></span><br /> <strong><span style="font-size: 18.0px">unsere fortschrittlichen ausr&uuml;stung</span></strong></p>
</p>
<p style="text-align: center"><strong><span style="font-size: 18.0px">unternehmensinformationen</span></strong></p>
<p style="text-align: center"><strong><span style="font-size: 18.0px">&nbsp;</span></strong></p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-zhotb" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-zhotb" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">FAQ</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-size: 14.0px">1. Preis Begriff: EXW, FOB, CFR oder CIF.</span><br /><span style="font-size: 14.0px">verschiffen seaport: Shanghai Hafen. f&uuml;r FOB, CFR oder CIF preis, bitte angeben, welche genaue modell sie ben&ouml;tigen, und teilen sie uns ihre bestellung menge, damit wir berechnen die lokalen transportkosten und seefracht.</span><br /><span style="font-size: 14.0px">2. MOQ: 1 s&auml;tze f&uuml;r Kundenspezifische</span><br /><span style="font-size: 14.0px">3. Zahlung: In Der Regel 30% durch T/T als ablagerung, balance durch T/T oder L/C am anblick vor versand. andere zahlungsweise k&ouml;nnen verhandelt werden.</span><br /><span style="font-size: 14.0px">4. lieferzeit: waren k&ouml;nnen versandfertig innerhalb von 10 werktagen nach erhalt der anzahlung.</span><br /><span style="font-size: 14.0px">5. garantie: 30 jahre</span></p>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/factory-selling-iec62196-type-2-plugsev-charging-cables/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
