<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Hongda cable YJV 4*70 low voltage electrical power cable &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/hongda-cable-yjv-470-low-voltage-electrical-power-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Fri, 06 Sep 2019 08:19:52 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.30</generator>
	<item>
		<title>Hongda cable YJV 4*70 low voltage electrical power cable</title>
		<link>https://german.baoliyy.com/hongda-cable-yjv-470-low-voltage-electrical-power-cable/</link>
				<comments>https://german.baoliyy.com/hongda-cable-yjv-470-low-voltage-electrical-power-cable/#respond</comments>
				<pubDate>Fri, 06 Sep 2019 08:19:52 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[zzhd]]></category>
		<category><![CDATA[electronic cable]]></category>
		<category><![CDATA[Hongda cable YJV 4*70 low voltage electrical power cable]]></category>
		<category><![CDATA[XLPE insulated copper electrical cable]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/hongda-cable-yjv-470-low-voltage-electrical-power-cable/</guid>
				<description><![CDATA[&#160; Hongda kabel yjv 4*70 niederspannung stromkabel Spezifikationen 0.6/1kv kabel ~26/35kv drei kerne cu/vpe/SWA/pvc hat gute elektrische F&#228;higkeit und Sicherheit, hochwarmfesten F&#228;higkeit 0.6/1kv kabel ~26/35kv drei kerne cu/vpe/SWA/pvc netzkabel Serie ist vor allem f&#252;r Verlegung innen, tunnel, Kanal und unter der erde, welle mit gro&#223;en Unterschieden der Stufe und anderen Bedingungen. Vpe-isolierte stromkabel wurden weit [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p style="text-align: center">&nbsp; <span style="font-size: 18.0px"><strong>Hongda kabel yjv 4*70 niederspannung stromkabel</strong></span></p>
<p><span style="font-size: 18.0px"><strong><span style="font-style: normal;line-height: normal;font-family: arial">Spezifikationen</span></strong></span></p>
<p><span style="font-family: arial;font-size: 9.0pt;line-height: normal">0.6/1kv kabel ~26/35kv drei kerne cu/vpe/SWA/pvc hat gute elektrische F&auml;higkeit und Sicherheit, hochwarmfesten F&auml;higkeit</span></p>
<p><span style="font-style: normal;font-weight: normal;font-size: 9.0pt;line-height: normal;font-family: arial">0.6/1kv kabel ~26/35kv drei kerne cu/vpe/SWA/pvc netzkabel Serie ist vor allem f&uuml;r Verlegung innen, tunnel, Kanal und unter der erde, welle mit gro&szlig;en Unterschieden der Stufe und anderen Bedingungen. Vpe-isolierte stromkabel wurden weit verbreitet in unserem Land mit den Vorteilen der gute elektrische F&auml;higkeit, versichern die Sicherheit, starke F&auml;higkeit zu widerstehen Kurzschluss, hohe Begriff Betriebstemperatur, und gro&szlig;e Volumen der strom umwandeln. Und dieses Kabel ist einfach zu beheben und Reparatur. Und so weiter</span></p>
<p><span style="font-style: normal;font-weight: normal;font-size: 9.0pt;line-height: normal;font-family: arial">&nbsp;</span></p>
<p><span style="font-style: normal;font-weight: normal;font-size: 9.0pt;line-height: normal;font-family: arial"><span style="font-size: 18.0px"><strong>Standards</strong></span></span></p>
<p><span style="font-family: arial;font-size: 9.0pt;line-height: normal">Iec60502- 2, iec60332, iec60754, und anderen Normen nur als bs, dn, oder dem Standard von den Clients erforderlich.</span></p>
<p><span style="font-style: normal;font-weight: normal;font-size: 9.0pt;line-height: normal;font-family: arial">&nbsp;</span></p>
<p><span style="font-style: normal;font-weight: normal;font-size: 9.0pt;line-height: normal;font-family: arial">Die Art Kabel und Anwendung 0.6/1kv</span></p>
<div style="overflow:auto"><table style="width: 478.5pt">
<tbody>
<tr align="left">
<td style="width: 39.0pt" valign="center">
<p><span style="font-size: 12.0pt">Art</span></p>
</td>
<td style="width: 206.5pt" valign="center">
<p><span style="font-size: 12.0pt">Namen</span></p>
</td>
<td style="width: 233.0pt" valign="center">
<p><span style="font-size: 12.0pt">Anwendung gebunden</span></p>
</td>
</tr>
<tr align="left">
<td valign="center">
<p><span style="font-size: 12.0pt">yjv</span></p>
</td>
<td valign="center">
<p><span style="font-size: 12.0pt">Kupfer vpe-isolierte pvc-ummantelte stromkabel</span></p>
</td>
<td rowspan="4" valign="center">
<p><span style="font-size: 12.0pt">Vor allem legte bei innen, kabel Slot, rohr und anderen Orten, die nicht ertragen starkem druck</span></p>
</td>
</tr>
<tr align="left">
<td valign="center">
<p><span style="font-size: 12.0pt">yjlv</span></p>
</td>
<td valign="center">
<p><span style="font-size: 12.0pt">Aluminium vpe-isolierte pvc-ummantelte stromkabel</span></p>
</td>
</tr>
<tr align="left">
<td valign="center">
<p><span style="font-size: 12.0pt">yjy</span></p>
</td>
<td valign="center">
<p><span style="font-size: 12.0pt">Kupfer vpe-isolierte pe-ummantelte stromkabel</span></p>
</td>
</tr>
<tr align="left">
<td valign="center">
<p><span style="font-size: 12.0pt">yjly</span></p>
</td>
<td valign="center">
<p><span style="font-size: 12.0pt">Aluminium vpe-isolierte pe-ummantelte stromkabel</span></p>
</td>
</tr>
<tr align="left">
<td valign="center">
<p><span style="font-size: 12.0pt">yjv22</span></p>
</td>
<td valign="center">
<p><span style="font-size: 12.0pt">Kupfer vpe-isolierte stahlband gepanzerten pvc-ummantelte stromkabel</span></p>
</td>
<td rowspan="4" valign="center">
<p><span style="font-size: 12.0pt">Vor allem legte bei innen, kabel Slot, rohr und anderen Orten, die ertragen starkem druck</span></p>
</td>
</tr>
<tr align="left">
<td valign="center">
<p><span style="font-size: 12.0pt">yjlv22</span></p>
</td>
<td valign="center">
<p><span style="font-size: 12.0pt">Aluminium vpe-isolierte stahlband gepanzerten pvc-ummantelte stromkabel</span></p>
</td>
</tr>
<tr align="left">
<td valign="center">
<p><span style="font-size: 12.0pt">yjv23</span></p>
</td>
<td valign="center">
<p><span style="font-size: 12.0pt">Kupfer vpe-isolierte stahlband gepanzerten pe-ummantelte stromkabel</span></p>
</td>
</tr>
<tr align="left">
<td valign="center">
<p><span style="font-size: 12.0pt">yjlv23</span></p>
</td>
<td valign="center">
<p><span style="font-size: 12.0pt">Aluminium vpe-isolierte stahlband gepanzerten pe-ummantelte stromkabel</span></p>
</td>
</tr>
<tr align="left">
<td valign="center">
<p><span style="font-size: 12.0pt">yjv32</span></p>
</td>
<td valign="center">
<p><span style="font-size: 12.0pt">Kupfer vpe-isolierte feinen stahldraht gepanzerten pvc-ummantelte stromkabel</span></p>
</td>
<td rowspan="4" valign="center">
<p><span style="font-size: 12.0pt">verlegt werden vertikal und ertragen konnte starkem druck</span></p>
</td>
</tr>
<tr align="left">
<td valign="center">
<p><span style="font-size: 12.0pt">yjlv32</span></p>
</td>
<td valign="center">
<p><span style="font-size: 12.0pt">Aluminium vpe-isolierte feinen stahldraht gepanzerten pvc-ummantelte stromkabel</span></p>
</td>
</tr>
<tr align="left">
<td valign="center">
<p><span style="font-size: 12.0pt">yjv33</span></p>
</td>
<td valign="center">
<p><span style="font-size: 12.0pt">Kupfer vpe-isolierte feinen stahldraht gepanzerten pe pvc-ummantelte stromkabel</span></p>
</td>
</tr>
<tr align="left">
<td valign="center">
<p><span style="font-size: 12.0pt">yjlv33</span></p>
</td>
<td valign="center">
<p><span style="font-size: 12.0pt">Aluminium vpe-isolierte feinen stahldraht gepanzerten pe pvc-ummantelte stromkabel</span></p>
</td>
</tr>
<tr align="left">
<td valign="center">
<p><span style="font-size: 12.0pt">yjav</span></p>
</td>
<td valign="center">
<p><span style="font-size: 12.0pt">Kupferleiter vpe-isolierte integrieren wasserdicht pvc-ummantelte stromkabel</span></p>
</td>
<td rowspan="2" valign="center">
<p><span style="font-size: 12.0pt">Vor allem legte bei innen, kabel Slot, rohr und Feuchtigkeit Ort, nicht ertragen starkem druck</span></p>
</td>
</tr>
<tr align="left">
<td valign="center">
<p><span style="font-size: 12.0pt">yjlav</span></p>
</td>
<td valign="center">
<p><span style="font-size: 12.0pt">Aluminium-leiter vpe-isolierte integrieren wasserdicht pvc-ummantelte stromkabel</span></p>
</td>
</tr>
</tbody>
</table></div>
</p>
</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/hongda-cable-yjv-470-low-voltage-electrical-power-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
