<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>iec standard aaac &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/iec-standard-aaac/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Wed, 11 Sep 2019 04:42:39 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.26</generator>
	<item>
		<title>Hot sale!!IEC standard AAAC electrical wire and cable</title>
		<link>https://german.baoliyy.com/hot-saleiec-standard-aaac-electrical-wire-and-cable/</link>
				<comments>https://german.baoliyy.com/hot-saleiec-standard-aaac-electrical-wire-and-cable/#respond</comments>
				<pubDate>Wed, 11 Sep 2019 04:42:39 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[jinshui]]></category>
		<category><![CDATA[AAAC]]></category>
		<category><![CDATA[electrical wire and cable]]></category>
		<category><![CDATA[iec standard aaac]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/hot-saleiec-standard-aaac-electrical-wire-and-cable/</guid>
				<description><![CDATA[Spezifikationen IEC standard AAAC elektrische draht und kabel IEC standard AAAC elektrische draht und kabel wurde weit verbreitet in power &#252;bertragung linien mit verschiedenen spannungs ebenen. &#160; 1. anwendungen IEC standard AAAC elektrische draht und kabelHatWeit verbreitet in power &#252;bertragung linien mit verschiedenen spannungs ebenen, weil sie haben gute eigenschaften wie einfache struktur, bequeme installation [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<h2>Spezifikationen</h2>
<div style="clear: both">IEC standard AAAC elektrische draht und kabel</div>
<div style="clear: both">IEC standard AAAC elektrische draht und kabel wurde weit verbreitet in power &uuml;bertragung linien mit verschiedenen spannungs ebenen.</p>
</div>
<div style="clear: both">&nbsp;</div>
<div>
<p><span style="color: #33cccc"><strong>1. anwendungen</strong></span></p>
<p><span style="line-height: normal">IEC standard AAAC elektrische draht und kabel</span><span style="line-height: normal">Hat</span>Weit verbreitet in power &uuml;bertragung linien mit verschiedenen spannungs ebenen, weil sie haben gute eigenschaften wie einfache struktur, bequeme installation und wartung, niedrigen kosten gro&szlig;e &uuml;bertragungs kapazit&auml;t. und sie sind auch geeignet f&uuml;r verlegung &uuml;ber fl&uuml;sse t&auml;ler und die orte, wo besondere geographische merkmale existieren.</p>
<p>&nbsp;</p>
<p><span style="color: #33cccc"><strong>2. Service Leistung</strong></span></p>
<p><span style="color: #000000"><strong>IEC standard AAAC elektrische draht und kabel</strong></span></p>
<p>(1). die zul&auml;ssige lange-zeit betriebs temperatur f&uuml;r luft leiter ist 70<sup>O</sup>C.</p>
<p>(2). unter dem umstand, dass seltene klima ist auftretenden und eis abdeckung rate niedrigen in schwere eis bereich, die gr&ouml;&szlig;ten stress von kabel zu den niedrigsten punkt der sag sollte nicht &uuml;berschreiten 60% der kurze- kurzzeitzerst&ouml;rungskraft.</p>
<p>(3). beim anschluss leiter, die leiter neben die anschluss rohr kann nicht sein prominente. sonst, die kraft auf die betriebs leiter wird unsymmetrisch. nach anschl&uuml;sse sind installieren, die anschluss rohr sollte gestrichen werden durch feuchtigkeit-beweis lack, um es vor korrosion zu sch&uuml;tzen.</p>
<p>(4). unter installaion, die arc downing stress von alle die leiter sollte die gleiche. mit in die zul&auml;ssige abstand von crossing geb&auml;ude oder dropping auf den boden, die stress kann 10-15% h&ouml;her als regelm&auml;&szlig;ige stress.</p>
<p>&nbsp;</p>
<p><span style="color: #33cccc"><strong>3. produkt Leistung</strong></span></p>
<p>IEC standard AAAC elektrische draht und kabel</p>
<p>(1). die elektrische leistung von AAC und ACSR ist angegeben in DC&Omega;/km (20<sup>O</sup>C). der widerstand der harten aluminium draht f&uuml;r litzen ist nicht gr&ouml;&szlig;er als 28,264 n&Omega;. m von internationalen standard wert.</p>
<p>(2). die bewertet zug festigkeit von AAC ist bezeichnet mit dem ergebnis von insgesamt kreuz-abschnitt von alle aluminium leiter multipliziert mit min. zug von entsprechenden gr&ouml;&szlig;e angegeben in die standard f&uuml;r aluminium draht.</p>
<p>(3). die bewertet zug strengh von ACSR ist bezeichnet mit summe von alle aluminium conductorstensile festigkeit und st&auml;hlen zug festigkeit.</p>
<p>A. die zug festigkeit von alle aluminium leiter ist bezeichnet mit dem ergebnis der alle kreuz-abschnitte von aluminium leiter multipliziert mit min. zug festigkeit von entsprechenden gr&ouml;&szlig;e angegeben in die standard f&uuml;r aluminium draht.</p>
<p>B. die zug festigkeit von alle stahl draht ist bezeichnet mit dem ergebnis der alle kreuz-abschnitte von stahl dr&auml;hte multipliziert durch die stress bei 1% dehnung von entsprechenden gr&ouml;&szlig;e angegeben in die standard f&uuml;r stahl draht.</p>
<p>&nbsp;</p>
<p><span style="color: #33cccc"><strong>4. Material Standard</strong></span></p>
<p>IEC standard AAAC elektrische draht und kabel</p>
<p>(1). die harte aluminium leiter verwendet f&uuml;r AAC und ACSR entspricht die standard GB/T 17048-1997 (entspricht IEC 60889: 1987).</p>
<p>(2). die zink beschichtet verwendet stahldraht f&uuml;r ACSR entspricht IEC 60888: 1987.</p>
<p>(3). produktion kann angeordnet nach kunden anforderungen f&uuml;r material standard, etc.</p>
<p>Bau von Alle Aluminium Leiter und Aluminium Leiter Stahl Verst&auml;rkt</p>
<p>&nbsp;</p>
<p><span style="color: #33cccc"><strong>5. chinesischen Standard</strong></span></p>
<p>IEC standard AAAC elektrische draht und kabel</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td>
<p>Neue Typ</p>
</td>
<td>
<p>Original Typ</p>
</td>
<td>
<p>Name</p>
</td>
<td>
<p>Palette von Schnitts Bereich</p>
</td>
</tr>
<tr>
<td>
<p>JL</p>
</td>
<td>
<p>LJ</p>
</td>
<td>
<p>Alle Aluminium Leiter</p>
</td>
<td>
<p>10-1500</p>
</td>
</tr>
<tr>
<td>
<p>JL/G1A JL/G1B JL/G2A JL/G2B JL/G3A</p>
</td>
<td>
<p>LGJ</p>
</td>
<td>
<p>Aluminium Leiter Stahl Verst&auml;rkt</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JL/G1AF JL/G2AF JL/G3AF</p>
</td>
<td>
<p>LGJF</p>
</td>
<td>
<p>Korrosion-Best&auml;ndig Aluminium Leiter Stahl Verst&auml;rkt</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JLHA1 JLHA2</p>
</td>
<td>
<p>LHAJ</p>
</td>
<td>
<p>Alle Aluminium Legierung Leiter</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JLHA1/G1A JLHA1/G1B JLHA1/G3A JLHA2/G1A JLHA2/G1B JLHA1/G3A</p>
</td>
<td>
<p>LHAGJ</p>
</td>
<td>
<p>Aluminium Legierung Leiter Stahl Verst&auml;rkt</p>
</td>
<td>
<p>16-1120</p>
</td>
</tr>
<tr>
<td>
<p>JL/LHA1 JL/LHA2</p>
</td>
<td>
<p>LLHAGJ</p>
</td>
<td>
<p>Aluminium Leiter Aluminium Legierung Verst&auml;rkt</p>
</td>
<td>
<p>16-1400</p>
</td>
</tr>
<tr>
<td>
<p>JL/LB1A</p>
</td>
<td>
<p>LLBGJ</p>
</td>
<td>
<p>Aluminium Leiter Stahl Beschichtet Aluminium Verst&auml;rkt</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JLHA2/LB1A JLHA1/LB1A</p>
</td>
<td>
<p>LHALBGJ</p>
</td>
<td>
<p>Aluminium Legierung Leiter Aluminium Beschichtet Stahl Verst&auml;rkt</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JG1A JG1B JG2A JG3A</p>
</td>
<td>
<p>GJ</p>
</td>
<td>
<p>Alle Stahl Litze</p>
</td>
<td>
<p>6-63 (27,1mm<sup>2</sup>-427mm<sup>2</sup>)</p>
</td>
</tr>
<tr>
<td>
<p>JLB1A JLB1B JLB2</p>
</td>
<td>
<p>LBGJ</p>
</td>
<td>
<p>Aluminium Beschichtete Stahl Leiter</p>
</td>
<td>
<p>4-200 (12mm<sup>2</sup>-600mm<sup>2</sup></p>
</td>
</tr>
</tbody>
</table></div>
</div>
<p>&nbsp;</p>
</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/hot-saleiec-standard-aaac-electrical-wire-and-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>high quality IEC standard AAAC cable wire for power transmission</title>
		<link>https://german.baoliyy.com/high-quality-iec-standard-aaac-cable-wire-for-power-transmission/</link>
				<comments>https://german.baoliyy.com/high-quality-iec-standard-aaac-cable-wire-for-power-transmission/#respond</comments>
				<pubDate>Wed, 11 Sep 2019 04:42:36 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[jinshui]]></category>
		<category><![CDATA[AAAC cable wire]]></category>
		<category><![CDATA[AAAC cable wire for power transmission]]></category>
		<category><![CDATA[iec standard aaac]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/high-quality-iec-standard-aaac-cable-wire-for-power-transmission/</guid>
				<description><![CDATA[&#160;Specifications &#160;&#160; IEC standard AAAC cable wire for power transmission &#160;&#160;IEC standard AAAC cable wire for power transmission&#160;has been widely used in power transmission lines with various voltage levels. &#160; 1.&#160;&#160;&#160;&#160;&#160;&#160; Applications &#160;&#160;&#160;IEC standard AAAC cable wire for power transmission&#160;has&#160;been widely used in power transmission lines with various voltage levels,because they have such good characteristics [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<h2>&nbsp;Specifications</h2>
<div style="clear: both">&nbsp;&nbsp; IEC standard AAAC cable wire for power transmission</div>
<div style="clear: both"><span style="line-height: normal">&nbsp;</span><span style="line-height: normal">&nbsp;IEC standard AAAC cable wire for power transmission&nbsp;</span>has been widely used in power transmission lines with various voltage levels. </p>
</div>
<div style="clear: both">&nbsp;</div>
<div>
<p>1.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Applications</p>
<p><span style="line-height: normal">&nbsp;</span><span style="line-height: normal">&nbsp;</span><span style="line-height: normal">&nbsp;IEC standard AAAC cable wire for power transmission&nbsp;</span><span style="line-height: normal">has&nbsp;</span>been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.</p>
<p>2.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Service Performance</p>
<p>(1).The permissible long-time operating temperature for aerial conductor is 70<sup>o</sup>C.</p>
<p>(2).Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area,the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.</p>
<p>(3).When connecting conductors,the conductor beside the connecting tube cant be prominent.Otherwise,the force on the operating conductors will be unbalanced.After connectors are install,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.</p>
<p>(4).Under installaion,the arc downing stress of all the conductors should be the same.With in the permissible distance of crossing buildings or dropping to the ground,the stress can be 10-15% higher than regular stress.</p>
<p>3.Product Performance</p>
<p>(1).The electrical performance of AAC and ACSR is indicated in DC&Omega;/km(20<sup>o</sup>C).The resistivity of the hard aluminum wire for stranded wires is not greater than 28.264 n&Omega;. m of international standard value.</p>
<p>(2).The rated tensile strength of AAC is denoted with the result of total cross-section of all aluminum conductors multiplied by min.tensile of corresponding size specified in the standard for aluminum wire.</p>
<p>(3).The rated tensile strengh of ACSR is denoted with sum of all aluminum conductorstensile strength and steels tensile strength.</p>
<p>a.The tensile strength of all aluminum conductors is denoted with the result of all cross-sections of aluminum conductors multiplied by min.tensile strength of corresponding size specified in the standard for aluminum wire.</p>
<p>b.The tensile strength of all steel wire is denoted with the result of all cross-sections of steel wires multiplied by the stress at 1% elongation of corresponding size specified in the standard for steel wire.</p>
<p>4.Material Standard</p>
<p>(1).The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889:1987).</p>
<p>(2).The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.</p>
<p>(3).Production can be arranged according to customers requirements for material standard,etc.</p>
<p>Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced</p>
<p>5.Chinese Standard</p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td>
<p>New Type</p>
</td>
<td>
<p>Original Type</p>
</td>
<td>
<p>Name</p>
</td>
<td>
<p>Range of Sectional Area</p>
</td>
</tr>
<tr>
<td>
<p>JL</p>
</td>
<td>
<p>LJ</p>
</td>
<td>
<p>All Aluminum Conductor</p>
</td>
<td>
<p>10-1500</p>
</td>
</tr>
<tr>
<td>
<p>JL/G1A JL/G1B JL/G2A JL/G2B JL/G3A</p>
</td>
<td>
<p>LGJ</p>
</td>
<td>
<p>Aluminum Conductor Steel Reinforced</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JL/G1AF JL/G2AF JL/G3AF</p>
</td>
<td>
<p>LGJF</p>
</td>
<td>
<p>Corrosion-Resistant Aluminum Conductor Steel Reinforced</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JLHA1&nbsp; JLHA2</p>
</td>
<td>
<p>LHAJ</p>
</td>
<td>
<p>All Aluminum Alloy Conductor</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JLHA1/G1A JLHA1/G1B JLHA1/G3A JLHA2/G1A JLHA2/G1B JLHA1/G3A</p>
</td>
<td>
<p>LHAGJ</p>
</td>
<td>
<p>Aluminum Alloy Conductor Steel Reinforced</p>
</td>
<td>
<p>16-1120</p>
</td>
</tr>
<tr>
<td>
<p>JL/LHA1&nbsp; JL/LHA2</p>
</td>
<td>
<p>LLHAGJ</p>
</td>
<td>
<p>Aluminum Conductor Aluminum Alloy Reinforced</p>
</td>
<td>
<p>16-1400</p>
</td>
</tr>
<tr>
<td>
<p>JL/LB1A</p>
</td>
<td>
<p>LLBGJ</p>
</td>
<td>
<p>Aluminum Conductor Steel Coated Aluminum Reinforced</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JLHA2/LB1A JLHA1/LB1A</p>
</td>
<td>
<p>LHALBGJ</p>
</td>
<td>
<p>Aluminum Alloy Conductor Aluminum Coated Steel Reinforced</p>
</td>
<td>
<p>16-1250</p>
</td>
</tr>
<tr>
<td>
<p>JG1A JG1B JG2A JG3A</p>
</td>
<td>
<p>GJ</p>
</td>
<td>
<p>All Steel Stranded Conductor</p>
</td>
<td>
<p>6-63(27.1mm<sup>2</sup>-427mm<sup>2</sup>)</p>
</td>
</tr>
<tr>
<td>
<p>JLB1A JLB1B&nbsp; JLB2</p>
</td>
<td>
<p>LBGJ</p>
</td>
<td>
<p>Aluminum Coated Steel Conductor</p>
</td>
<td>
<p>4-200(12mm<sup>2</sup>-600mm<sup>2</sup></p>
</td>
</tr>
</tbody>
</table></div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/high-quality-iec-standard-aaac-cable-wire-for-power-transmission/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
