<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Low Voltage Copper Conductor XLPE Insulation PVC Sheath Power Cable &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/low-voltage-copper-conductor-xlpe-insulation-pvc-sheath-power-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Mon, 16 Sep 2019 07:43:26 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>Low Voltage Copper Conductor XLPE Insulation PVC Sheath Power Cable</title>
		<link>https://german.baoliyy.com/low-voltage-copper-conductor-xlpe-insulation-pvc-sheath-power-cable/</link>
				<comments>https://german.baoliyy.com/low-voltage-copper-conductor-xlpe-insulation-pvc-sheath-power-cable/#respond</comments>
				<pubDate>Mon, 16 Sep 2019 07:43:26 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[yifang]]></category>
		<category><![CDATA[Low Volatage Cable]]></category>
		<category><![CDATA[Low Voltage Copper Conductor XLPE Insulation PVC Sheath Power Cable]]></category>
		<category><![CDATA[power cable]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/low-voltage-copper-conductor-xlpe-insulation-pvc-sheath-power-cable/</guid>
				<description><![CDATA[Niederspannung Kupferleiter Vpe-isolierung PVC-Mantel Netzkabel 1. nennspannung: Uo/U: 0,6/1kV2. No. Von core: Single-core, zwei-core, drei-core, vier-core, f&#252;nf-core, drei kern und erde (Drei prim&#228;re leiter und eine Neutrale leiter), drei kern und zwei ((Drei prim&#228;re leiter und Zwei neutralleiter), vier kern und erde ((Vier prim&#228;re leiter und Eine Neutrale leiter).3. Die h&#246;chsten erlaubt betriebstemperatur des leiters [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<h2>Niederspannung Kupferleiter Vpe-isolierung PVC-Mantel Netzkabel</h2>
<p><span style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 15.6px;font-size: 14.0px">1. nennspannung: Uo/U: 0,6/1kV</span><br /><span style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 15.6px;font-size: 14.0px">2. No. Von core: Single-core, zwei-core, drei-core, vier-core, f&uuml;nf-core, drei kern und erde (Drei prim&auml;re leiter und eine Neutrale leiter), drei kern und zwei ((Drei prim&auml;re leiter und Zwei neutralleiter), vier kern und erde ((Vier prim&auml;re leiter und Eine Neutrale leiter).</span><br /><span style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 15.6px;font-size: 14.0px">3. Die h&ouml;chsten erlaubt betriebstemperatur des leiters f&uuml;r langfristige arbeits ist &deg; c. In kurzschluss (Max. Langfristige ist nicht mehr als 5 sekunden). die h&ouml;chste temperatur f&uuml;r leiter ist nicht mehr als 160oC.</span><br /><span style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 15.6px;font-size: 14.0px">4. D. C. widerstand des leiters entspricht mit den bestimmungen der IEC 60502.</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px"><span style="color: #333333;line-height: 15.6px">5. Die umgebungstemperatur sollte nicht niedriger als 0oC wenn legen. andernfalls es sollte vorgew&auml;rmt.</span>&nbsp;</span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div style="overflow:auto"><table style="border-collapse: collapse;width: 586.0px;margin-left: 5.4pt;height: 661.0px">
<tbody>
<tr style="height: 17.25pt">
<td style="width: 219.625px;padding: 0.0pt 5.4pt;border: 1.0pt solid windowtext" colspan="2" valign="top">
<p><span style="font-size: 12.0pt">typ</span></p>
</td>
<td style="width: 202.625px;padding: 0.0pt 5.4pt" rowspan="2" valign="top">
<p><span style="font-size: 12.0pt">Name</span></p>
</td>
<td style="width: 116.625px;padding: 0.0pt 5.4pt" rowspan="2" valign="top">
<p><span style="font-size: 12.0pt">geeignete fl&auml;chen</span></p>
</td>
</tr>
<tr style="height: 30.75pt">
<td style="width: 112.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">C</span><span style="font-size: 12.0pt">opper leiter</span></p>
</td>
<td style="width: 91.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">AL leiter</span></p>
</td>
</tr>
<tr style="height: 39.0pt">
<td style="width: 112.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJV</span></p>
</td>
<td style="width: 91.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJLV</span></p>
</td>
<td style="width: 202.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">vpe-isolierte kabel ummantelte mit PVC</span></p>
</td>
<td style="width: 116.625px;padding: 0.0pt 5.4pt" rowspan="2" valign="top">
<p><span style="font-size: 12.0pt">innen, tunnel, kabelkanal</span></p>
</td>
</tr>
<tr style="height: 30.0pt">
<td style="width: 112.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJY</span></p>
</td>
<td style="width: 91.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJLY</span></p>
</td>
<td style="width: 202.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">vpe-isolierte kabel ummantelte mit polyethylen</span></p>
</td>
</tr>
<tr style="height: 30.75pt">
<td style="width: 112.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJV22</span></p>
</td>
<td style="width: 91.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJLV22</span></p>
</td>
<td style="width: 202.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">vpe-isolierte kabel ummantelte mit PVC und gepanzerte mit stahlband</span></p>
</td>
<td style="width: 116.625px;padding: 0.0pt 5.4pt" rowspan="2" valign="top">
<p><span style="font-size: 12.0pt">erdverlegung im boden und kapazit&auml;t der lager bestimmte mechanische kraft,</span><span style="font-size: 12.0pt">&nbsp;</span><span style="font-size: 12.0pt">nicht richtige in der pipeline</span></p>
</td>
</tr>
<tr style="height: 30.05pt">
<td style="width: 112.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJV23</span></p>
</td>
<td style="width: 91.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJLV23</span></p>
</td>
<td style="width: 202.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">vpe-isolierte kabel ummantelte mit polyethylen und gepanzerte mit stahlband</span></p>
</td>
</tr>
<tr style="height: 29.9pt">
<td style="width: 112.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJV32</span></p>
</td>
<td style="width: 91.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJLV32</span></p>
</td>
<td style="width: 202.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">vpe-isolierte kabel ummantelte mit PVC und gepanzerte mit d&uuml;nnen stahldraht</span></p>
</td>
<td style="width: 116.625px;padding: 0.0pt 5.4pt" rowspan="4" valign="top">
<p><span style="font-size: 12.0pt">das bett der fluss und flachen meer, als die verbindungsleitung zwischen den beiden plattformen von &ouml;l und gas station im wasser, die kapazit&auml;t der lager zugkraft.</span></p>
</td>
</tr>
<tr style="height: 29.75pt">
<td style="width: 112.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJV33</span></p>
</td>
<td style="width: 91.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJLV33</span></p>
</td>
<td style="width: 202.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">vpe-isolierte kabel ummantelte mit polyethylen und gepanzerte mit d&uuml;nnen stahldraht</span></p>
</td>
</tr>
<tr style="height: 29.5pt">
<td style="width: 112.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJV42</span></p>
</td>
<td style="width: 91.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJLV42</span></p>
</td>
<td style="width: 202.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">vpe-isolierte kabel ummantelte mit PVC und gepanzerte mit dicken stahldraht</span></p>
</td>
</tr>
<tr style="height: 29.45pt">
<td style="width: 112.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJV43</span></p>
</td>
<td style="width: 91.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">YJLV43</span></p>
</td>
<td style="width: 202.625px;padding: 0.0pt 5.4pt" valign="top">
<p><span style="font-size: 12.0pt">vpe-isolierte kabel ummantelte mit polyethylen und gepanzerte mit dicken stahldraht</span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-y2qrq" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-y2qrq" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Unternehmensinformationen</span></div>
<div style="padding: 10.0px 0">
</p>
<p>&nbsp;</p>
<p style="line-height: 15.0pt;text-align: left"><strong><span style="font-family: arial , sans-serif;color: #0070c0">f&uuml;gt: No. 7 Changchun Stra&szlig;e, Zhengzhou, 450001, China</span></strong></p>
<p style="line-height: 15.0pt;text-align: left"><strong><span style="font-family: arial , sans-serif;color: #0070c0">Website:<span style="line-height: 18.0px">&nbsp;</span></span><span style="font-family: verdana , sans-serif;color: #444444"><span style="font-family: arial , sans-serif;color: #0070c0">www.yifangcable.cn</span></span><span style="font-family: arial , sans-serif;color: #0070c0">;<span style="line-height: 18.0px">&nbsp;</span></span><span style="font-family: verdana , sans-serif;color: #444444"><span style="font-family: arial , sans-serif;color: #0070c0">www.yifangcable.com</span></span></strong></p>
<p style="line-height: 15.0pt;text-align: left"><strong><span style="font-family: arial , sans-serif;color: #0070c0">Skype: eva. wang789 Mobile: 008613839025708</span></strong></p>
<p>&nbsp;</p>
<p style="line-height: 15.0pt;text-align: left"><strong><span style="font-family: arial , sans-serif;color: #0070c0">Tel: 008637156500766</span></strong></p>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/low-voltage-copper-conductor-xlpe-insulation-pvc-sheath-power-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>