<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>NA2XS (F)2Y cable &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/na2xs-f2y-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Mon, 16 Sep 2019 08:00:41 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.31</generator>
	<item>
		<title>N2XS (F)2Y / NA2XS (F)2Y cable</title>
		<link>https://german.baoliyy.com/n2xs-f2y-na2xs-f2y-cable/</link>
				<comments>https://german.baoliyy.com/n2xs-f2y-na2xs-f2y-cable/#respond</comments>
				<pubDate>Mon, 16 Sep 2019 08:00:41 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[yifang]]></category>
		<category><![CDATA[N2XS (F)2Y cable]]></category>
		<category><![CDATA[NA2XS (F)2Y cable]]></category>
		<category><![CDATA[XLPE Cable]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/n2xs-f2y-na2xs-f2y-cable/</guid>
				<description><![CDATA[HV kabel/N2XS (F) 2Y kabel/NA2XS (F) 2Y kabel &#160; Uo/U-6/10 kV, 12/20 kV, 18/30kV IEC 60502-2/DIN VDE 0276-620 Anwendung Die single-core-kabel mit isolierung von vernetzte polyethylen (VPE) und l&#228;ngs wasser-blocking elemente sind entworfen f&#252;r transfer und verteilung von elektrischen power mit nennspannung Uo/ U 6/10; 12/20; 18/30 kV und frequenz 50 hz in st&#228;dtischen und [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><strong><span style="font-family: arial , sans-serif;color: black;font-size: 13.5pt">HV kabel/N2XS (F) 2Y kabel/NA2XS (F) 2Y kabel</span></strong></p>
<p><strong></strong>&nbsp;</p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Uo/U-6/10 kV, 12/20 kV, 18/30kV IEC 60502-2/DIN VDE 0276-620</span></p>
</p>
<p><strong><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Anwendung</span></strong></p>
</p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Die single-core-kabel mit isolierung von vernetzte polyethylen (VPE) und l&auml;ngs wasser-blocking elemente sind entworfen f&uuml;r transfer und verteilung von elektrischen power mit nennspannung Uo/ U 6/10; 12/20; 18/30 kV und frequenz 50 hz in st&auml;dtischen und bezirk elektrische netzwerke und f&uuml;r elektrische versorgung von transformator der unterstationen, kleine und mittlere industrie pflanzen.</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">&nbsp;</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Sie sind geeignet f&uuml;r den einsatz in verteilung installationen, elektrische power stationen und industrielle systeme. Die kabel sind f&uuml;r feste montage in linien mit unbegrenzte unterschied ebenen, innen installationen, in kabel kan&auml;le, leitungen und wellen, &uuml;ber regale und grills direkt unterirdischen in graben und outdoor unterstand.</span></p>
<p><span style="font-family: verdana , arial , helvetica , sans-serif">&nbsp;</span></p>
<div style="overflow:auto"><table style="width: 569.0px" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 14.85pt" align="left">
<td style="width: 426.75pt" colspan="2" valign="top">
<p><strong><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Kabel bau</span></strong></p>
</td>
</tr>
<tr style="height: 31.1pt" align="left">
<td style="width: 137.35pt" valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Bau</span></p>
</td>
<td style="width: 289.4pt" valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Nach IEC 60502-2</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">DIN VDE 0276-620</span></p>
</td>
</tr>
<tr style="height: 45.6pt" align="left">
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Leiter</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Innere semi-leitf&auml;hige schicht</span></p>
</td>
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Cu und Al gestrandet verdichtet, nach IEC 60228 klasse 2 und VDE 0295 klasse 2</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Semi-leitf&auml;higen XLPE verbindung</span></p>
</td>
</tr>
<tr style="height: 15.55pt" align="left">
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Isolierung</span></p>
</td>
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">XLPE verbindung</span></p>
</td>
</tr>
<tr style="height: 14.05pt" align="left">
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">&Auml;u&szlig;ere semi-leitf&auml;hige schicht</span></p>
</td>
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Semi-leitf&auml;higen XLPE verbindung</span></p>
</td>
</tr>
<tr style="height: 19.45pt" align="left">
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Wasser wider element</span></p>
</td>
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Schicht von semi-leitf&auml;higen wasser absorbieren b&auml;nder</span></p>
</td>
</tr>
<tr style="height: 17.55pt" align="left">
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Metall bildschirm</span></p>
</td>
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Kupfer dr&auml;hte konzentrisch gelegt und einem kontakt von kupfer band</span></p>
</td>
</tr>
<tr style="height: 61.4pt" align="left">
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Wasser wider element</span></p>
</td>
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">-ICH option-wasser absorbieren isolierende</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Band</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">-II option-wasser absorbieren pulver</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Und eine schicht von kunststoff band</span></p>
</td>
</tr>
<tr style="height: 13.65pt" align="left">
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Mantel</span></p>
</td>
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">PE verbindung</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-size: 10.5pt;font-family: arial , sans-serif">Farbe:</span><span style="font-size: 10.5pt;font-family: arial , sans-serif">Rot, schwarz oder als ihr antrag</span></p>
<p><span style="font-size: 9.0pt;font-family: arial , sans-serif">&nbsp;</span></p>
<p><span style="float: none"><span style="font-size: 10.5pt;font-family: arial , sans-serif">Leiter querschnitt bereich ist bis zu 1000mm2</span></span></p>
<p><span style="font-size: 9.0pt;font-family: arial , sans-serif">&nbsp;</span></p>
<p><span style="float: none"><span style="font-size: 10.5pt;font-family: arial , sans-serif">F&uuml;r andere detaillierte informationen, pls kontaktieren sie uns direkt.</span></span></p>
</p>
</p>
</p>
<p><span style="font-size: 9.0pt;font-family: arial , sans-serif">&nbsp;</span></p>
</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/n2xs-f2y-na2xs-f2y-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
		<item>
		<title>N2XS (F)2Y / NA2XS (F)2Y cable 6/10kV, 12/20kV, 18/30kV</title>
		<link>https://german.baoliyy.com/n2xs-f2y-na2xs-f2y-cable-6-10kv-12-20kv-18-30kv/</link>
				<comments>https://german.baoliyy.com/n2xs-f2y-na2xs-f2y-cable-6-10kv-12-20kv-18-30kv/#respond</comments>
				<pubDate>Mon, 16 Sep 2019 08:00:40 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[yifang]]></category>
		<category><![CDATA[N2XS (F)2Y cable]]></category>
		<category><![CDATA[NA2XS (F)2Y cable]]></category>
		<category><![CDATA[XLPE Cable]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/n2xs-f2y-na2xs-f2y-cable-6-10kv-12-20kv-18-30kv/</guid>
				<description><![CDATA[HV kabel/N2XS (F) 2Y kabel/NA2XS (F) 2Y kabel &#160; Uo/U-6/10 kV, 12/20 kV, 18/30kV IEC 60502-2/DIN VDE 0276-620 anwendung die single-core kabel mit isolierung von vernetztes polyethylen (XLPE) und l&#228;ngs wasserblockierenden elemente sind f&#252;r &#252;bertragung und verteilung von elektrischer energie mit nennspannung Uo/U 6/10; 12/20; 18/30 kV und frequenz 50Hz in st&#228;dtischen und bezirk elektrische [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p><strong><span style="font-family: arial , sans-serif;color: black;font-size: 13.5pt">HV kabel/N2XS (F) 2Y kabel/NA2XS (F) 2Y kabel</span></strong></p>
<p><strong></strong>&nbsp;</p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Uo/U-6/10 kV, 12/20 kV, 18/30kV IEC 60502-2/DIN VDE 0276-620</span></p>
<p><strong><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">anwendung</span></strong></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">die single-core kabel mit isolierung von vernetztes polyethylen (XLPE) und l&auml;ngs wasserblockierenden elemente sind f&uuml;r &uuml;bertragung und verteilung von elektrischer energie mit nennspannung Uo/U 6/10; 12/20; 18/30 kV und frequenz 50Hz in st&auml;dtischen und bezirk elektrische netzwerke und f&uuml;r stromversorgung von transformator der unterstationen, kleine und mittlere industrieanlagen.</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">&nbsp;</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">sie sind geeignet f&uuml;r den einsatz in verteilung installationen, elektrische kraftwerke und industriellen systemen. die kabel sind f&uuml;r feste montage in linien mit unbegrenzte unterschied ebenen, indoor installationen, in kabelkan&auml;len, leitungen und wellen, &uuml;ber regale und grills direkt u-bahn in graben und outdoor unterstand.</span></p>
<p><span style="font-family: verdana , arial , helvetica , sans-serif">&nbsp;</span></p>
<div style="overflow:auto"><table style="width: 569.0px" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 14.85pt" align="left">
<td style="width: 426.75pt" colspan="2" valign="top">
<p><strong><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">kabelaufbau</span></strong></p>
</td>
</tr>
<tr style="height: 31.1pt" align="left">
<td style="width: 137.35pt" valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">bau</span></p>
</td>
<td style="width: 289.4pt" valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">nach IEC 60502-2</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">DIN VDE 0276-620</span></p>
</td>
</tr>
<tr style="height: 45.6pt" align="left">
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">leiter</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">innere semi-leitf&auml;hige schicht</span></p>
</td>
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">Cu und Al gestrandet verdichtet, nach IEC 60228 klasse 2 und VDE 0295 klasse 2</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">halb leitenden vpe-verbindung</span></p>
</td>
</tr>
<tr style="height: 15.55pt" align="left">
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">isolierung</span></p>
</td>
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">vpe-verbindung</span></p>
</td>
</tr>
<tr style="height: 14.05pt" align="left">
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">&auml;u&szlig;ere semi-leitf&auml;hige schicht</span></p>
</td>
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">halb leitenden vpe-verbindung</span></p>
</td>
</tr>
<tr style="height: 19.45pt" align="left">
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">wasserbest&auml;ndigkeit element</span></p>
</td>
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">schicht von halb leitenden wasser absorbieren b&auml;nder</span></p>
</td>
</tr>
<tr style="height: 17.55pt" align="left">
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">metall bildschirm</span></p>
</td>
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">kupfer dr&auml;hte konzentrisch gelegt und einem kontakt von kupferband</span></p>
</td>
</tr>
<tr style="height: 61.4pt" align="left">
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">wasserbest&auml;ndigkeit element</span></p>
</td>
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">-ich option-wasseraufnahme isolierende</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">band</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">-II option-wasser absorbierenden pulver</span></p>
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">und eine schicht von kunststoffband</span></p>
</td>
</tr>
<tr style="height: 13.65pt" align="left">
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">mantel</span></p>
</td>
<td valign="top">
<p><span style="font-family: arial , helvetica , sans-serif;font-size: 14.0px">PE verbindung</span></p>
</td>
</tr>
</tbody>
</table></div>
<p><span style="font-size: 10.5pt;font-family: arial , sans-serif">farbe:</span><span style="font-size: 10.5pt;font-family: arial , sans-serif">rot, schwarz oder als ihr antrag</span></p>
<p><span style="font-size: 9.0pt;font-family: arial , sans-serif">&nbsp;</span></p>
<p><span style="float: none"><span style="font-size: 10.5pt;font-family: arial , sans-serif">leiter querschnitt bereich ist bis zu 1000mm2</span></span></p>
<p><span style="font-size: 9.0pt;font-family: arial , sans-serif">&nbsp;</span></p>
<p><span style="float: none"><span style="font-size: 10.5pt;font-family: arial , sans-serif">f&uuml;r andere detaillierte informationen, pls kontaktieren sie uns direkt.</span></span></p>
</p>
</p>
</p>
<p><span style="font-size: 9.0pt;font-family: arial , sans-serif">&nbsp;</span></p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/n2xs-f2y-na2xs-f2y-cable-6-10kv-12-20kv-18-30kv/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
