<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>UG AL\/CU XLPE Insulated &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/ug-al-cu-xlpe-insulated/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Fri, 06 Sep 2019 08:23:41 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>UG AL/CU XLPE Insulated LT cable</title>
		<link>https://german.baoliyy.com/ug-al-cu-xlpe-insulated-lt-cable/</link>
				<comments>https://german.baoliyy.com/ug-al-cu-xlpe-insulated-lt-cable/#respond</comments>
				<pubDate>Fri, 06 Sep 2019 08:23:41 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[zzhd]]></category>
		<category><![CDATA[LT cable]]></category>
		<category><![CDATA[UG AL\/CU XLPE Insulated]]></category>
		<category><![CDATA[UG AL\/CU XLPE Insulated LT cable]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/ug-al-cu-xlpe-insulated-lt-cable/</guid>
				<description><![CDATA[Unsere firma ist ein berufs hersteller von UG AL/CU Vpe-isolierte LT kabel. Wir haben die beste R &#38; D, produktion, vertrieb und service-team und moderne enterprise-management-organisation &#160; Anwendung: Geeignet f&#252;r den einsatz in verteilung linien oder feste installation &#160; Betriebs Eigenschaften: * Max. kurzschluss temperatur des leiters ist nicht &#252;berschreiten (5 s maximale dauer): Kreuz-abschnitt [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p>Unsere firma ist ein berufs hersteller von UG AL/CU Vpe-isolierte LT kabel. Wir haben die beste R &amp; D, produktion, vertrieb und service-team und moderne enterprise-management-organisation</p>
<p>&nbsp;</p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 24.0px;color: #ff0000;font-size: 16.0px"><strong>Anwendung:</strong></span></p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 21.0px;font-size: 14.0px">Geeignet f&uuml;r den einsatz in verteilung linien oder feste installation</span></p>
<p style="font-family: arial;line-height: 18.0px" align="left">&nbsp;</p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 24.0px;color: #ff0000;font-size: 16.0px"><strong>Betriebs Eigenschaften:</strong></span></p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 21.0px;font-size: 14.0px">* Max. kurzschluss temperatur des leiters ist nicht &uuml;berschreiten (5 s maximale dauer):</span></p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 21.0px;font-size: 14.0px">Kreuz-abschnitt von leiter &le;300mm2 160</span><span style="font-size: 9.0pt">&deg;C</span><span style="line-height: 21.0px;font-size: 14.0px">;</span></p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 21.0px;font-size: 14.0px">Kreuz-abschnitt von leiter&gt; 300mm2 140<span style="line-height: 18.0px;font-size: 9.0pt">&deg;C</span>&nbsp;.</span></p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 21.0px;font-size: 14.0px">* Die umgebungs temperatur unter installation von kabel sollte nicht unter 0<span style="line-height: 18.0px;font-size: 9.0pt">&deg;C</span>&nbsp;.</span></p>
<p style="font-family: arial;line-height: 18.0px" align="left"><span style="line-height: 21.0px;font-size: 14.0px">* Die biegen radius von kabel sollte nicht weniger als 10 mal der durchmesser der kabel.</span></p>
<p style="font-family: arial;line-height: 18.0px" align="left">&nbsp;</p>
<p style="font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">(1). die lange-zeit zul&auml;ssige betrieb des leiters darf nicht h&ouml;her sein als 70</span><span style="line-height: 21.0px;font-size: 14.0px">&deg;C</span><span style="line-height: 21.0px;font-size: 14.0px">.</span><br /><span style="line-height: 21.0px;font-size: 14.0px">(2). leiter maximale kurzschluss (nicht mehr als 5 sekunden) temperatur darf nicht h&ouml;her sein als 160 &deg;C.</span><br /><span style="line-height: 21.0px;font-size: 14.0px">(3). die power kabel ist nicht begrenzte durch drop in, wenn sie gelegt, und die umgebungs temperatur darf nicht niedriger sein als 0 &deg;C.</span><br /><span style="line-height: 21.0px;font-size: 14.0px">(4). perfekte chemische stabilit&auml;t, best&auml;ndig gegen s&auml;uren, laugen, fett und organischen l&ouml;sungsmitteln, und flamme.</span><br /><span style="line-height: 21.0px;font-size: 14.0px">(5). licht gewicht, perfekte biegen eigenschaften, installiert und einfach gehalten werden und bequem.</span></p>
<p style="font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">Wir bieten gepanzerte typ und nicht-gepanzerte typ f&uuml;r die power kabel oben.</span></p>
<p style="font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">&nbsp;</span></p>
<p style="font-family: arial;line-height: 18.0px;text-align: left"><span style="color: #ff0000"><strong><span style="line-height: 21.0px;font-size: 14.0px">Betriebs erhaltung, wenn kabel verlegung</span></strong></span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;color: #ff0000;font-size: 14.0px">In Luft</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">1. die single-core-kabel sind paralled gelegt, der abstand zwischen dem kabel center ist 2 mal durchmesser der csble f&uuml;r querschnitt des leiters &le; 185mm<sup>2</sup>Und 90mm f&uuml;r querschnitt des leiters &ge;240mm<sup>2</sup>.</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">2. umgebungs luft temperatur: 40 &deg;C</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">3. Max. zul&auml;ssige kontinuierliche opesating temperatur von leiter: 70 &deg;C</span></p>
<p style="font-family: arial;line-height: 18.0px;text-align: left">&nbsp;</p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;color: #ff0000;font-size: 14.0px">Direkt im boden</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">1. wenn die single-core-kabel sind installiert separat, der abstand zwischen die kabel center ist 2 mal durchmesser der kabel</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">2. Solid temperatur: 25 &deg;C</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">3. Max. zul&auml;ssige kontinuierliche betriebs temperatur des leiters: 70 &deg;C</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">4. Solid thermische widerstand: 10 &deg;C m/w</span></p>
<p style="margin-left: 30.0px;font-family: arial;line-height: 18.0px;text-align: left"><span style="line-height: 21.0px;font-size: 14.0px">5. tiefe von verlegung: 0,7 m</span></p>
<p>&nbsp;</p>
<div style="overflow:auto"><table style="color: #000000;font-family: arial;font-size: 12.0px;line-height: 18.0px;text-align: left" border="0">
<tbody>
<tr>
<td style="overflow: hidden" colspan="4">
<p>VPE-KABEL DER TYP UND WICHTIGSTEN ANWENDUNG</p>
</td>
</tr>
<tr>
<td style="overflow: hidden" colspan="2">
<p>TYP</p>
</td>
<td style="overflow: hidden" rowspan="2">
<p>Beschreibung</p>
</td>
<td style="overflow: hidden" rowspan="2">
<p>Wichtigsten Anwendung</p>
</td>
</tr>
<tr>
<td style="overflow: hidden">
<p>CU CORE</p>
</td>
<td style="overflow: hidden">
<p>AI CORE</p>
</td>
</tr>
<tr>
<td style="overflow: hidden">
<p>YJV</p>
<p>Oder YJY</p>
</td>
<td style="overflow: hidden">
<p>YJLV</p>
<p>Oder YJLY</p>
</td>
<td style="overflow: hidden">
<p>Vpe-isolierte,</p>
<p>PVC oder PE mantel power kabel</p>
</td>
<td style="overflow: hidden">
<p>Gelten f&uuml;r die verlegung im innenbereich,</p>
<p>In tunnel und kabel graben.</p>
<p>Nicht in der lage zu tragen externe mechanische kr&auml;fte.</p>
<p>Single-core-kabel in magnetische kanal ist nicht zul&auml;ssig.</p>
</td>
</tr>
<tr>
<td style="overflow: hidden">
<p>YJV22</p>
<p>Oder YJY23</p>
</td>
<td style="overflow: hidden">
<p>YJLV22</p>
<p>Oder YJLY23</p>
</td>
<td style="overflow: hidden">
<p>Vpe-isolierte,</p>
<p>Stahl gepanzerten, PVC oder PE mantel power kabel</p>
</td>
<td style="overflow: hidden">
<p>Gelten f&uuml;r die verlegung im innenbereich,</p>
<p>In tunnel, kabel graben und direkt im boden.</p>
<p>Werden in der lage zu tragen externe mechanische kr&auml;fte,</p>
<p>Aber nicht in der lage zu tragen gro&szlig;e ziehen kr&auml;fte.</p>
<p>&nbsp;</p>
</td>
</tr>
<tr>
<td style="overflow: hidden">
<p>YLV32</p>
<p>Oder YJV33</p>
</td>
<td style="overflow: hidden">
<p>YJLV</p>
<p>Oder YJLY 33</p>
</td>
<td style="overflow: hidden">
<p>Vpe-isolierte</p>
<p>Feine stahl draht gepanzerte, PVC oder PE mantel power kabel</p>
</td>
<td style="overflow: hidden">
<p>Gelten f&uuml;r die verlegung im innenbereich,</p>
<p>In tunnel, kabel graben und direkt im boden.</p>
<p>Werden in der lage zu tragen externe machanical kraft</p>
<p>Und moderate zugkraft</p>
</td>
</tr>
<tr>
<td style="overflow: hidden">
<p>YJV42</p>
<p>Oder YJV43</p>
</td>
<td style="overflow: hidden">
<p>YJLV42</p>
<p>Oder YJLV43</p>
</td>
<td style="overflow: hidden">
<p>Vpe-isolierte,</p>
<p>Dicken stahldraht gepanzerten,</p>
<p>PVC oder PE mantel power kabel</p>
</td>
<td style="overflow: hidden">
<p>Gelten f&uuml;r verlegung in wasser und meeresboden.</p>
<p>Werden in der lage zu tragen possitive druck und zugkraft</p>
</td>
</tr>
</tbody>
</table></div>
<p style="font-family: arial;line-height: 18.0px;text-align: left">&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-4sb4s" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-4sb4s" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Hei&szlig;er verkauf produkte</span></div>
<div style="padding: 10.0px 0">
<div style="overflow:auto"><table style="border-collapse: collapse;background-color: #ffffff;width: 80.0%" border="1">
<tbody>
<tr style="height: 34.0px">
<td style="height: 34.0px;width: 18.6842%"><strong><span style="font-size: 14.0px">ABC kabel</span></strong></td>
<td style="height: 34.0px;width: 34.3158%"><strong><span style="font-size: 14.0px">Elektrische draht</span></strong></td>
<td style="height: 34.0px;width: 41.0%"><strong><span style="font-size: 14.0px">Power kabel</span></strong></td>
</tr>
<tr style="height: 122.0px">
<td style="height: 122.0px;width: 18.6842%"></td>
<td style="height: 122.0px;width: 34.3158%"></td>
<td style="height: 122.0px;width: 41.0%"></td>
</tr>
<tr style="height: 37.0px">
<td style="height: 37.0px;width: 18.6842%"><span style="font-size: 14.0px"><strong>Gepanzerten stromkabel</strong></span></td>
<td style="height: 37.0px;width: 34.3158%"><span style="font-size: 14.0px"><strong><span style="color: #333333;font-style: normal;background-color: #ffffff;float: none">Konzentrischen</span>Kabel</strong></span></td>
<td style="height: 37.0px;width: 41.0%"><span style="font-size: 14.0px"><strong>Steuer kabel</strong></span></td>
</tr>
<tr style="height: 181.0px">
<td style="height: 181.0px;width: 18.6842%"></td>
<td style="height: 181.0px;width: 34.3158%"></td>
<td style="height: 181.0px;width: 41.0%">&nbsp;</td>
</tr>
</tbody>
</table></div>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-8gz4e" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-8gz4e" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Zertifizierungen</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/ug-al-cu-xlpe-insulated-lt-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
