<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Underground copper power cable with XLPE insulation &#8211; JYTOP Cable</title>
	<atom:link href="https://german.baoliyy.com/tag/underground-copper-power-cable-with-xlpe-insulation/feed/" rel="self" type="application/rss+xml" />
	<link>https://german.baoliyy.com</link>
	<description>Herstellung AAC / AAAC / ACSR-LEITER, VPE-Kabel, PVC-Kabel, ABC-Kabel, Stromkabel</description>
	<lastBuildDate>Wed, 11 Sep 2019 04:35:48 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.30</generator>
	<item>
		<title>Underground copper power cable with XLPE insulation</title>
		<link>https://german.baoliyy.com/underground-copper-power-cable-with-xlpe-insulation/</link>
				<comments>https://german.baoliyy.com/underground-copper-power-cable-with-xlpe-insulation/#respond</comments>
				<pubDate>Wed, 11 Sep 2019 04:35:48 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[jinshui]]></category>
		<category><![CDATA[Underground copper power cable with XLPE insulatio]]></category>
		<category><![CDATA[Underground copper power cable with XLPE insulation]]></category>

		<guid isPermaLink="false">https://german.baoliyy.com/underground-copper-power-cable-with-xlpe-insulation/</guid>
				<description><![CDATA[1 bau Leiter: Kupfer (oder Aluminium) Isolierung: XLPE F&#252;llstoff: Nicht hygroskopisch Polypropylen (PP) Binder Band: Nicht-gewebe Innere Abdeckung: PVC Metallic Armour: Verzinktem Stahl Draht Armour (SWA) Nicht-magnetische Stahl Draht Armour (nur f&#252;r single-core) Aluminium Draht Armoured (AWA, nur f&#252;r single-core) &#196;u&#223;ere Mantel: PVC (oder PE) 2 Standard IEC 60502, GB/T 12706 3 anwendung Verwendet f&#252;r [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="line-height: 24.0px;font-size: medium">1 bau</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">Leiter: Kupfer (oder Aluminium)</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">Isolierung: XLPE</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">F&uuml;llstoff: Nicht hygroskopisch Polypropylen (PP)</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">Binder Band: Nicht-gewebe</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">Innere Abdeckung: PVC</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">Metallic Armour: Verzinktem Stahl Draht Armour (SWA)</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">Nicht-magnetische Stahl Draht Armour (nur f&uuml;r single-core)</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">Aluminium Draht Armoured (AWA, nur f&uuml;r single-core)</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">&Auml;u&szlig;ere Mantel: PVC (oder PE)</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="line-height: 24.0px;font-size: medium">2 Standard</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">IEC 60502, GB/T 12706</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="line-height: 24.0px;font-size: medium">3 anwendung</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">Verwendet f&uuml;r fest installationen wie elektrische power verteilung netzwerke oder industrie installationen, die ist gelegt in hohe herbst bereich, in der lage zu tragen externe mechanische kraft, und bestimmte zugkraft.</span></strong><strong></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="line-height: 24.0px;font-size: medium">4 betriebs Eigenschaften</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">Nennspannung: 0,6/1 (1,2) kV</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">Max. Betriebs Temperatur von Leiter: 90<sup><span style="font-size: xx-small">O</span></sup>C</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">Max. kurzschluss Temperatur von Leiter: 250<sup><span style="font-size: xx-small">O</span></sup>C</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">Min. Umgebungs Temperatur unter Installation: 0<sup><span style="font-size: xx-small">O</span></sup>C</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: comic sans ms , sans-serif;color: #000000"><strong><span style="font-size: 9.0pt">Wenn die gepanzert einzigen core kabel verwendet f&uuml;r Alternative Strom (AC) system, die r&uuml;stung material sollte nicht-magnetische.</span></strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333">&nbsp;</p>
<div style="overflow:auto"><table style="line-height: 18.0px;width: 652.0px;font-family: arial , helvetica , sans-serif;color: #333333;font-size: 12.0px" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 29.25pt" align="middle">
<td style="margin: 0.0px;width: 3.0cm">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Typ</span></p>
</td>
<td style="margin: 0.0px;width: 9.0cm">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Beschreibung</span></p>
</td>
<td style="margin: 0.0px;width: 70.9pt">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Anzahl der kerne</span></p>
</td>
<td style="margin: 0.0px;width: 77.95pt">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Nenn querschnitt des leiters</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA/PVC Power Kabel</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small">2</span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJLV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA/PVC Power Kabel</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJV72</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/Nicht-magnetische SWA oder AWA/PVC Power Kabel</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small">2</span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJLV72</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/Nicht-magnetische SWA oder AWA/PVC Power Kabel</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJV33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA/PE Power Kabel</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small">2</span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJLV33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA/PE Power Kabel</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Z-YJV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA Flamme-hemmende Power Kabel</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small">2</span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Z-YJLV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA Flamme-hemmende Power Kabel</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">WDZ-YJY33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA Niedrigen Rauch Halogen Freies oder Null Halogen (LSHF oder LSZH) flammhemmende Power Kabel</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small">2</span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">WDZ-YJLY33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA Niedrigen Rauch Halogen Freies oder Null Halogen (LSHF oder LSZH) flammhemmende Power Kabel</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">N-YJV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA Feuer-best&auml;ndig Power Kabel</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1,5 ~ 1000mm<sup><span style="font-size: xx-small">2</span></sup></span></p>
</td>
</tr>
</tbody>
</table></div>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333">&nbsp;</p>
<p>&nbsp;</p>
<div style="overflow:auto"><table style="margin-left: auto;margin-right: auto" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="middle">
<td style="width: 122.4pt" colspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Typ</span></p>
</td>
<td style="width: 108.0pt" rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Name</span></p>
</td>
<td style="width: 195.7pt" rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Anwendung</span></p>
</td>
</tr>
<tr align="middle">
<td style="width: 59.4pt">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Cu</span></p>
<p align="center"><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Conducto</span></p>
</td>
<td style="width: 63.0pt">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Al</span></p>
<p align="center"><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Leiter</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Vpe-isolierte, PVC oder PE ummantelte stromkabel</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">F&uuml;r legen innen, tunnel, kanal und unterirdischen. Nicht in der lage zu tragen externe mechanische kraft w&auml;hrend gelegt.</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJY</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium">22</span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV<sub><span style="font-size: medium">22</span></sub></span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Vpe-isolierte, stahl gepanzerten, PVC oder PE ummantelte stromkabel</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">F&uuml;r legen innen, tunnel, kanal und unterirdischen. In der lage zu tragen externe mechanische kraft, aber nicht in der lage zu tragen gro&szlig;e zugkraft.</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium">23</span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLY<span style="font-size: medium"><sub>2</sub><sub>3</sub></span></span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium">32</span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV<sub><span style="font-size: medium">32</span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Vpe-isolierte, feinen stahldraht gepanzerten, PVC oder PE ummantelte stromkabel</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">F&uuml;r die verlegung in welle mit gro&szlig;er unterschied von ebene. In der lage zu tragen externe mechanische kraft, und moderate zugkraft.</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium">42</span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV<sub><span style="font-size: medium">42</span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Vpe-isolierte, starke stahl gepanzerte, PVC oder PE ummantelte stromkabel</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">F&uuml;r die verlegung in welle mit gro&szlig;er unterschied von ebene. In der lage zu tragen externe mechanische kraft, und moderate zugkraft.</span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
</p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333">&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://german.baoliyy.com/underground-copper-power-cable-with-xlpe-insulation/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
